Lenovo ThinkEdge SE350 V2 Server Product Guide (2024)

Table of Contents
Abstract Change History Introduction Did you know? Key features View in Augmented Reality Components and connectors System architecture Standard specifications Models Processors Memory options I/O expansion Internal storage Controllers for internal storage Intel VROC onboard RAID Internal drive options Optical drive Network Modules Network adapters GPU adapters Cooling Power supplies Power cords Systems management Local management System status with XClarity Mobile Remote management XCC2 Platinum Lenovo XClarity Provisioning Manager Lenovo XClarity Administrator Lenovo XClarity Integrators Lenovo XClarity Essentials Lenovo XClarity Energy Manager Lenovo Capacity Planner Security System Lockdown Mode SED encryption in factory orders System Guard Platform Firmware Resiliency - Lenovo ThinkShield Intel Transparent Supply Chain Mounting options Mounting components Desktop mount Wall or DINmount Security bezel 1U rack installation Short-depth 2U rack installation Mounting options and power Operating system support Hyperconverged infrastructure support VMware vSAN Microsoft Azure Stack HCI Physical and electrical specifications Operating environment Acoustical noise emissions Ambient temperature management Environment Shock and vibration Particulate contamination Warranty and Support Services Regulatory compliance Top-of-rack Ethernet switches Uninterruptible power supply units Power distribution units Rack cabinets KVM console options Lenovo Financial Services Seller training courses Related publications and links Related product families Trademarks References

Abstract

The SE350 V2is a purpose-built server that is half the width and significantly shorter than a traditional server, small footprint making it ideal for deployment in tight spaces. It can be mounted on a wall, ceiling mount,placed on a shelf or mounted in a rack. The ThinkEdgeSE350 V2 server puts increased processing power, storage and network closer to where data is generated. For customers that want to install server outside data center looking for reduced latency by processing at the edge.

This product guide provides essential pre-sales information to understand the ThinkEdge SE350 V2server, its key features and specifications, components and options, and configuration guidelines. This guide is intended for technical specialists, sales specialists, sales engineers, IT architects, and other IT professionals who want to learn more about the SE350 V2 and consider its use in IT solutions.

Change History

Changes in the May 17, 2024 update:

  • Updated the following under Mounting options section
    • The 1U2N Enclosure comes with two node fillers to ensure correct airflow if a node space is not populated
    • The 2U2N Enclosure comes with two node fillers to ensure correct airflow if a node space is not populated

Introduction

The ThinkEdge SE350 V2 is a purpose-built server that is half the width and significantly shorter than a traditional server, making it ideal for deployment in tight spaces. It can bemounted on a wall,ceiling mount, placed on a desk or mounted in a rack. The ThinkEdge SE350 V2 puts increased processing power, storage and network closer to where data is generated, allowing actions resulting from the analysis of that data to take place more quickly.

Target workloads for the manufacturing, industrial and retail markets:hybrid clouds at the edge deployment, virtualization, NFV, workload consolidation, web host, management server, edge storage server.


Figure 1. Lenovo ThinkEdge SE350 V2

Did you know?

The ThinkEdge SE350 V2 fits those customers that want to install a server outside the data center lookingfor reduced latency by processing at the edge, avoidingtransmission of data between the core and edge where possible and also adhering to the regulatory security requirements of the geography and industry by storing and analyzing data at the edge.The ThinkEdge SE350 V2 has acompact design, low power usage, and high performance are just the right combination for edge locations. It can be wall mounted, placed on a desk or installed in a rack. It is also designed to operate in a semi rugged environment, 0°C to 55°C, dust and vibration.

Key features

The ThinkEdge SE350 V2 is a purpose-built server that is half the width and significantly shorter than a traditional server, making it ideal for deployment in tight spaces. The 3.2liter case can be mounted on a wall, ceiling mount, placed on deskor mounted in a rack.

The ThinkEdge SE350 V2 puts increased processing power, storage and network closer to where data is generated, allowing actions resulting from the analysis of that data to take place more quickly. The server has wired connections up to 25GbE.

Since these edge servers are typically deployed outside of secure data centers, they include technology that encrypts the data stored on the device if it is tampered with, only enabling authorized users to accessit.

Scalability and performance

The SE350 V2 offers numerous features to boost performance, improve scalability and reduce costs:

  • Support a single processor from the Intel Xeon D Processor family. Supports processors up to 16cores, core speeds of up to 2.1GHz, and TDP ratings of up to 100W.
  • Intelligent and adaptive system performance with Intel Technology 2.0 allows processor cores to run at maximum speeds during peak workloads by temporarily going beyond processor TDP.
  • Intel Hyper-Threading Technology boosts performance for multithreaded applications by enabling simultaneous multithreading within each processor core, up to two threads per core.
  • Intel Virtualization Technology integrates hardware-level virtualization hooks that allow operating system vendors to better use the hardware for virtualization workloads.
  • Support for up to 4 TruDDR4 memory DIMMs an up to 256 GB of memory using 64 GB DIMMs.
  • Up to 4 x SATA/NVMe 2.5-inch 7mm HS drives; 2 x 2.5-inch 15mm HS drives.
  • Supports 1 or 2 additional M.2 NVMedrives for OS boot and applications (RAID 1), allowing the convenience of separating application code from data.
  • The use of NVMe drives increased performance over SATA drives, in terms of throughput, bandwidth, and latency.
  • 1GbE I/O board or 10 GbE/25GbESFP28 I/O board to support low and high-speed networking to back-end servers.
  • No PCIe slot (noGPU support, nooptionalNetwork Adapters support).

Availability and serviceability

The SE350 V2 provides many features to simplify serviceability and increase system uptime:

  • Supports remote management, including remote control functions down to the UEFI level (most models) makes managing the edge servers easy even without onsite IT personnel.
  • ECC memory and memory RAS features.
  • Two redundant external AC Adapter power suppliesand three fans to provide improved availability.
  • Built-in XClarity Controller continuously monitors system parameters, triggers alerts, and performs recovery actions in case of failures to minimize downtime.
  • Built-in diagnostics in UEFI, using Lenovo XClarity Provisioning Manager, speed up troubleshooting tasks to reduce service time.
  • Lenovo XClarity Provisioning Manager collects and saves service data to USB key drive or remote CIFS share folder, for troubleshooting and to reduce service time.
  • Auto restart in the event of a loss of AC power
  • Support for the XClarity Administrator Mobile app running on a supported smartphone and connected to the server through the service-enabled USB port, enables additional local systems management functions.
  • Three-year customer-replaceable unit and onsite limited warranty, 9 x 5 next business day. Optional service upgrades are available.

Manageability and security

Systems management features simplify local and remote management of the SE350 V2:

  • The server includes XClarity Controller 2 (XCC2) to monitor server availability. Optional upgrade to XCC Platinum to provide remote control (keyboard video mouse) functions, support for the mounting of remote media files (ISO and IMG image files), boot capture, power capping and new XCC2 Platinum features. New XCC2 Platinum features include System Guard, new security modes including a CNSA-compliant mode, FIPS 140-3 and NIST 800-193 support, and a new Neighbor Group feature.
  • LenovoXClarity Administrator offers comprehensive hardware management tools that help to increase uptime, reduce costs and improve productivity through advanced server management capabilities.
  • IT Administrators can securely claim and activate the SE350 V2 remotely through the ThinkShield Key Vault Portal, available on the web. They can also manage and unlock their global IoT edge fleet for initial operation and in case of tamper. The ThinkShield Edge Mobile Management app enables Edge Users to securely claim and activate the ThinkSystem SE350 V2 in an easy to use Web UI.
  • New UEFI-basedLenovo XClarity Provisioning Manager, accessible from F1 during boot, provides system inventory information, graphical UEFI Setup, platform update function, RAID Setup wizard, operating system installation function, and diagnostic functions.
  • Support for Lenovo XClarity Energy Manager, which captures real-time power and temperature data from the server and provides automated controls to lower energy costs.
  • Integrated Trusted Platform Module (TPM) 2.0 support enables advanced cryptographic methods, such as digital signatures and remote attestation.
  • Supports Secure Boot to ensure only a digitally signed operating system can be used.
  • Industry-standard Advanced Encryption Standard (AES) NI support for faster, stronger encryption.
  • Intel Execute Disable Bit functionality can prevent certain classes of malicious buffer overflow attacks when combined with a supported operating system.
  • Intel Trusted Execution Technology provides enhanced security through hardware-based resistance to malicious software attacks, allowing an application to run in its own isolated space, protected from all other software running on a system.

View in Augmented Reality

View the SE350 V2 in augmented reality (AR) using your smartphone or tablet.

Simply follow these steps:

  1. Scan the QR code* with the camera app on your phone
  2. Point your phone at a flat surface
  3. Wait a few seconds for the model to appear

Once the server appears, you can move your phone around it. You can also drag or rotate the server to reposition it.

For more information about the AR viewer, see the article "Introducing the Augmented Reality Viewer for Lenovo Servers", available from https://lenovopress.lenovo.com/lp1952

* If you're viewing this document on your phone or tablet, simply tap the QR code

Components and connectors

The ports on the front of the ThinkEdgeSE350 V2 serverdepend on which network module is installed.

The following figure shows server with the 1GbE network module installed. With this network module, the server has wired connectivity capabilities. Four 1GbE Ethernet ports, two 2.5Gigabit Ethernet ports, and 1portfor managementLAN.


Figure 2. Front view of the ThinkEdgeSE350 V2 server with4 x 7mm 2.5” HS and 1GbEnetwork module

The following figure shows server with the 10/25 GbEnetwork module installed. With this network module, the server has wired connectivity capabilities. Four 10/25 GbE SFP28ports, two 2.5Gigabit Ethernet ports, and 1portfor managementLAN.


Figure 3. Front view of the ThinkEdgeSE350 V2 server with4 x 7mm 2.5” HS and 10/25 GbE network module

The following figure shows server with 1GbE module, 1GbE Ethernet ports, two 2.5Gigabit Ethernet ports, and 1portfor managementLAN.

Lenovo ThinkEdge SE350 V2 Server Product Guide (5)

Figure 4. Front view of the ThinkEdgeSE350 V2 server with 2x 15mm 2.5” HS and 1GbEnetwork module.

The following two figures show supported power options for the server.


Figure 5. Rear view of the ThinkEdgeSE350 V2 with DC power


Figure 6. Rear view of the ThinkEdge SE350 V2 with AC power

The following figure shows the locations of key components inside the server.


Figure 7. Internal view of the ThinkEdge SE350 V2

System architecture

The following figure shows the architectural block diagram of the SE350 V2 system, showing the major components and connections.

Tip: The wrench icons show where the local and remote management functions are enabled

Figure 8. SE350 V2 system board - architectural block diagram

The system board connects to a network module which provides all wired network connections. Two network modules are offered. The block diagrams are shown in the following figures. All wired connections are at the front of the server.

Figure 9. SE350 V2 network modules - architectural block diagrams

Standard specifications

The following table lists the standard specifications.

Table 1. Standard specifications
ComponentsSpecification
Machine types7DA9 - SE350 V2 - 3 year warranty
7DBK - Lenovo ThinkEdge SE350 V2 1U2N and 2U2N Enclosure - 3 year warranty
Form factorEdge server,1U high
ProcessorOne Intel Xeon D-2700 Series processor (formerly codenamed "Icelake D"). Supports processors up to 16 cores, core speeds of up to 2.1 GHz, and TDP ratings of up to 100W. Processor is soldered onto system board.
Memory4 DIMM slots. The processor has 4 memory channels, with 1 DIMM per channel. Lenovo TruDDR4 DIMMs operating at 3200 MHz. RDIMMsare supported
Memory maximumUp to 256GB with 4x 64 GB RDIMMs
Memory protectionECC, SDDC(for x4-based memory DIMMs)
Drive bays

2.5-inch 7mm drive bays:

  • Up to 4x 2.5-inch 7mm hot-swap bays (NVMe/SATA)

2.5-inch 15mm drive bays:

  • Up to 2x 2.5-inch 15mm hot-swap bays (NVMe)

Internal drives for OS boot:

  • I/O module supporting up to two 2280 NVMe M.2 drives
Maximum data storage

NVMe drives:

  • 15.36 TB using 2x 7.68TB 15mm NVMe drives or 4x 3.84 7mm NVMe drives

SATA drives:

  • 30.72TB using 4x7.68TB 7mm SATA drives
Storage controller
  • Boot drives:
    • Onboard NVMe controller supporting RAID 0, 1 (with Intel VROC RAID support)
  • Data drives:
    • Onboard SATA/NVMe controller supporting RAID 0, 1, 5, 10 (with Intel VROC RAID support)
Network interfaces

Networking depends the network module selected:

  • 10/25GbE I/O module
    • 4x 25GbE or 10GbE SFP28ports (depends on CPU), 2x 2.5GbE RJ45 ports, 1x 1GbE RJ45 dedicated port for remote management.
  • 1GbE I/O module
    • 4x1GbE RJ45ports, 2x 2.5GbE RJ45 ports, 1x 1GbE RJ45 dedicated port for remote management.
PCI Expansion slotsNone
Ports

Front: 2x USB 3.2G1 Type-A ports, 1x USB 3.2G1 Type-Cport (for display), 1xUSB 2.0G1 Type-Cport for local systems management.

Rear: power connectors, 1x RJ-45 RS-232 serial console connector,PMB status LED, 2x threaded studs for grounding.

CoolingThree non-hot-swap 40 mm fans (all 3 standard), N+1 redundant in most configurations.
VideoEmbedded graphics with 16 MB memory with 2D hardware accelerator, integrated into the XClarity Controller 2 management controller. Maximum resolution is 1920x1200 32bpp at 60Hz.
Power supply

Choices for power input:

  • External AC Power Supply (230V/115V) (5°C to 40°C with node, 5°C to 30°C on rack)
  • Direct DC Power Connection (12-48V) (0°C to 55°C)
  • Internal AC Power Supply (230V/115V)(0°C to 55°C)
Systems managementOperator panel with status LEDs. Dedicated ports for local management (USB type-C for use with mobile app) and remote management (RJ45 Ethernet ports). Remote management can also be performed. XClarity Controller 2 (XCC2) embedded management controller, XClarity Administrator centralized infrastructure delivery, XClarity Integrator plugins, and XClarity Energy Manager centralized server power management. Optional XClarity Controller Advanced to enable remote control functions. ThinkShield Edge Mobile Management mobile app and XClarity Mobile app for local onsite SE350 V2 server management.
Security featuresThinkShield Key Vault Portal web site for security management. Trusted Platform Module, supporting TPM 2.0. In China only, optional Nationz TPM 2.0. Front Securitybezel, Kensington cable slot with intelligent lock position switch, G-sensor trigger for motion detection, intrusion detection, self-encrypting drive (SED) support, power-on password, administrator's password.
Operating systems supportedMicrosoft Windows Server, Red Hat Enterprise Linux, SUSE Linux Enterprise Server, VMware ESXi. Ubuntu Server certification. See the Operating system support section for specifics.
Mounting optionsDIN rail wall mount, ceiling mount, 1U rack mount (2 servers), 2U short-depth rack mount (2 servers). Available Securitybezel with dust filter.
Limited warrantyThree-yearcustomer-replaceable unit and onsite limited warranty with 9x5 next business day (NBD).
Service and supportOptional service upgrades are available through Lenovo Services: 4-hour or 2-hour response time, 6-hour fix time, 1-year or 2-year warranty extension, software support for Lenovo hardware and some third-party applications.
DimensionsHeight: 41.7 mm (1.64 in.), width: 209 mm (8.23 in.), depth: 384 mm (15.12 in.)
Volume3.2 liters
WeightMaximum: 3.75 kg (8.3 lb)

Models

ThinkEdge SE350 V2 models can be configured by using the Lenovo Data Center Solution Configurator (DCSC).

Configure-to-order (CTO) models are used to create models with factory-integrated server customizations. One CTO model is available for the SE350 V2 as listed in the following table:

  • The CTO1WW base CTO model is for general business and is selectable by choosing General Purpose mode in DCSC.
Table 2. Base CTO models
DescriptionMachine Type/Model
General purpose
ThinkEdge SE350 V2 - 3 year Warranty7DA9CTO1WW
Lenovo ThinkEdge SE350 V2 1U2N Enclosure7DBKCTO1WW
Lenovo ThinkEdge SE350 V2 2U2N Enclosure7DBKCTO2WW

Processors

The SE350 V2supports processors in the Intel Xeon D-2700 family of processors (formerly codenamed "IcelakeD"). The server supports one processor and the processor is soldered on the system board.

The table below lists the supported processors.

All supported processors have the following characteristics:

  • AI capable: Intel AVX-512, VNNI, OpenVINO
  • Intel Turbo Boost 3.1
  • Intel Hyper-Threading Technology
  • Intel Virtualization Technology (VT-c, VT-x, VT-d)
  • Intel AES New Instructions
  • Intel Trusted Execution Technology
  • Converged Boot Guard (CBnT)
  • Intel Software Guard Extensions (SGX)
  • Intel Boot Guard
  • Faster Boot with Slim Bootloader
  • Time Coordinated Computing (TCC)

Part numbers: There are no part numbers for processors because there are no field upgrades supported.

Table 3. Processor options for the SE350 V2
Feature code*Description
BS3V / BS40ThinkEdge SE350 V2/SE360 V2 Planar with Intel Xeon D-2712T 4C 65W 1.9 GHz
BS3W / BS41ThinkEdge SE350 V2/SE360 V2 Planar with Intel Xeon D-2733NT 8C 80W 2.1 GHz
BS3X/ BS42ThinkEdge SE350 V2/SE360 V2 Planar with Intel Xeon D-2775TE 16C 100W 2.0 GHz

* The second feature code is for CTO orders from NA and LA geographies, and for Brazil

The following table lists the features of the supported processors.

Table 4. Processor specifications
Intel modelCores /
Threads
HTTBBase
Frequency
Max Turbo
Frequency
L3 CacheEthernet modeMemory
channels
Memory
bus
TDP
D-2712T4YY1.90 GHz3.0 GHz15 MB50 G42667 MHz65 W
D-2733NT8YY2.10 GHz3.2 GHz15 MB50 G42667MHz80 W
D-2775TE16YY2.00 GHz3.1 GHz25 MB100 G42933 MHz100 W

Note: 10/25GbE I/O module LAN speed depend on CPU ethernet mode, 4x 10GbE (max 50 G) or 4x 25GbE (max 100G)
Note:20-core processor support: The processors listed here have up to 16 cores. The server also supports 20-core processors, however these are currently only available via special bid/CORE. Please contact your Lenovo sales representative.

Memory options

The server uses processors with 4 memory channels and supports 1 DIMM per channel, for a total of 4 DIMMs. The server supports up to 256GB of memory using 4x 64 GB RDIMMs.

The following table lists the memory options that are available for the server.

Lenovo TruDDR4 memory uses the highest quality components that are sourced from Tier 1 DRAM suppliers and only memory that meets the strict requirements of Lenovo is selected. It is compatibility tested and tuned to maximize performance and reliability. From a service and support standpoint, Lenovo TruDDR4 memory automatically assumes the system warranty, and Lenovo provides service and support worldwide.

Table 5. Supported memory options
Part
number
Feature
code
DescriptionMinimum
supported
Maximum
supported
RDIMMs
4X77A08634B965ThinkSystem 32GB TruDDR4 3200 MHz (2Rx8 1.2V) RDIMM14
4X77A08633B964ThinkSystem 32GB TruDDR4 3200 MHz (2Rx4 1.2V) RDIMM14
4X77A08632B963ThinkSystem 16GB TruDDR4 3200 MHz (2Rx8 1.2V) RDIMM14
4X77A08635B966ThinkSystem 64GB TruDDR4 3200 MHz (2Rx4 1.2V) RDIMM14

The following rules apply when selecting the memory configuration:

  • DIMM installation sequence 1, 4, 2 & 3
  • One DIMM per channel only
  • Three DIMMsare not supported
  • The server supports RDIMMs
  • Mix of 2Rx4 and 2Rx8 based DIMMs across channels are not supported
  • Mix of 16GB 2Rx8& 32GB 2Rx8across channels are supported
  • Mix of 32GB 2Rx4 & 64GB 2Rx4 across channelsare supported
  • Memory mirroring and memory rank sparing are not supported
  • Server supports Independent mode
  • Rank sparing, ADDC, channel mirroring, hemisphere modes, and 2LM are not supported with Software Guard Extensions (SGX)

The following memory protection technologies are supported:

  • ECC detection/correction
  • SDDC (for x4-based memory DIMMs; look for "x4" in the DIMM description)

I/O expansion

The SE350 V2 does not support PCIe I/O slots.

Internal storage

The internal storage of the SE350 V2 server is implemented as follows:

  • Up to 4x SATA/NVMe 2.5-inch 7mm drives or 2x NVMe 2.5-inch 15mm drives.
  • NVMe 2.5-inch drives with PCIe 4.0 interface.
  • Boot drives are installed on I/O module with dedicated slot, either one or two 2280 NVMe M.2 drives with PCIe gen3 are supported.

The following modulesare supported.

Table 6. SSD module options
Part
number
Feature
code
Description7mm SSD15mm SSD
4XF7A86281BS48ThinkEdge SE350 V2 7mm SSD Module0-4 (NVMe/SATA)--
4XF7A86280BS47ThinkEdge SE350 V2 15mm SSD Module--0-2 (all NVMe)

Controllers for internal storage

The SE350 V2 supports the following for internal storage:

  • Onboard NVMe controller supporting RAID 0, 1 (with Intel VROC RAID support) - boot drives
  • Onboard SATA/NVMe controller supporting RAID 0, 1, 5, 10 (with Intel VROC RAID support) - data drives

Intel VROC onboard RAID

Intel VROC (Virtual RAID on CPU) is a feature of the Intel processor that enables RAID support.
There are two separate functions of VROC in the SE350 V2:

  • Intel VROC SATA RAID, formerly known as Intel RSTe
  • Intel VROC NVMe RAID

VROC SATA RAID (RSTe) is available and supported with all SATA drives, both SATA SSDs and SATAHDDs. It offers a 6 Gb/s connection to each drive and on the SE350 V2 implements RAID levels 0, 1, 5,and 10. RAID 1 is limited to 2 drives per array, and RAID 10 is limited to 4 drives per array. Hot-spare functionality is also supported.

VROC NVMe RAID offers RAID support for any NVMe drives directly connected to the ports on the server's
system board. On the SE350 V2, it implements RAID levels 0, 1, 5, and 10. RAID 1 is limited to 2 drives per array, and RAID 10 is limited to 4 drives per array. Hot-spare functionality is also supported.

The following options are available as follows:

  • VROC NVMe RAID on the SE350 V2 by default is disabled and does not support NVMe RAID. In configuratorselecting "none" would mean default, same as JBOD.
  • Selecting VROC Standard, feature code BR9B, to support RAID-0/1/10.
  • Selecting VROCPremium, feature code B96G, to support RAID-0/1/5/10.

VROCStandard or Premium are fulfilled as a Feature on Demand (FoD) license and is activated via the XCC management processor user interface.

Table 7. VROC upgrade
Part
number
Feature
code
Description
4L47A39164B96G / BS7NIntel VROC (VMD NVMe RAID) Premium
4L47A83669BR9B / BS7MIntel VROC (VMD NVMe RAID) Standard

VROC Premium is only needed on the SE350 V2 for RAID-5 support with NVMe drives. You do not need the VROC Premium license upgrade under any of the following conditions:

  • If you have SATA drives connected to the onboard SATA ports, you do not need VROC Premium.
  • If you are using RAID 0, 1 or 10 with NVMe drives, you do not need VROC Premium.

Virtualization support: Virtualization support for Intel VROC is as follows:

  • VROC SATA RAID (RSTe): VROC SATA RAID is not supported by virtualization hypervisors such as ESXi, KVM, Xen, and Hyper-V. Virtualization is only supported on the onboard SATA ports in AHCI (non-RAID) mode.
  • VROC (VMD) NVMe RAID: VROC (VMD) NVMe RAID is supported by ESXi, KVM, Xen, and Hyper-V. ESXi support is limited to RAID 1 only; other RAID levels are not supported. Windows and Linux OSes support VROC RAID NVMe, both for host boot functions and for guest OS function, and RAID-0, 1, 5, and 10 are supported.

Internal drive options

The SE350 V2 supports the following type of drive bays.

  • 2.5-inch 7mm drive bays:
    • 7mm 2.5-inch hot-swap 6 Gb SATA SSDs
    • 7mm 2.5-inch hot-swap PCIe 4.0 NVMe SSDs
  • 2.5-inch 15mm drive bays:
    • 15mm 2.5-inch hot-swap PCIe 4.0 NVMe SSDs
  • M.2 drives for boot:
    • 2280 NVMe M.2 drives

The following table lists the supported drive options.

Table 8. Supported list of drives
Part
number
Feature
code
DescriptionMax
Qty
7mm 2.5-inch hot-swap 6 Gb SATA SSDs
4XB7A17106BK79ThinkSystem 7mm S4520 240GB Read Intensive SATA 6Gb HS SSD4
4XB7A17107BK7AThinkSystem 7mm S4520 480GB Read Intensive SATA 6Gb HS SSD4
4XB7A17108BK7BThinkSystem 7mm S4520 960GB Read Intensive SATA 6Gb HS SSD4
4XB7A78622BM8EThinkSystem 7mm S4520 1.92TB Read Intensive SATA 6Gb HS SSD4
4XB7A78623BM8DThinkSystem 7mm S4520 3.84TB Read Intensive SATA 6Gb HS SSD4
4XB7A78624BM8CThinkSystem 7mm S4520 7.68TB Read Intensive SATA 6Gb HS SSD4
4XB7A82264BQ1UThinkSystem 7mm 5400 PRO 240GB Read Intensive SATA 6Gb HS SSD4
4XB7A82265BQ1VThinkSystem 7mm 5400 PRO 480GB Read Intensive SATA 6Gb HS SSD4
4XB7A82266BQ1WThinkSystem 7mm 5400 PRO 960GB Read Intensive SATA 6Gb HS SSD4
4XB7A82267BR13ThinkSystem 7mm 5400 PRO 1.92TB Read Intensive SATA 6Gb HS SSD4
4XB7A82268BR12ThinkSystem 7mm 5400 PRO 3.84TB Read Intensive SATA 6Gb HS SSD4
4XB7A82269BR11ThinkSystem 7mm 5400 PRO 7.68TB Read Intensive SATA 6Gb HS SSD4
7mm 2.5-inch hot-swap PCIe 4.0 NVMe SSDs
4XB7A82851BS45ThinkSystem 7mm U.3 7450 MAX 800GB Mixed Use NVMe PCIe 4.0 x4 HS SSD4
4XB7A82853BPZ4ThinkSystem 7mm U.3 7450 PRO 960GB Read Intensive NVMe PCIe 4.0 x4 HS SSD4
4XB7A82855BPZ5ThinkSystem 7mm U.3 7450 PRO 1.92TB Read Intensive NVMe PCIe 4.0 x4 HS SSD4
4XB7A82856BPZ6ThinkSystem 7mm U.3 7450 PRO 3.84TB Read Intensive NVMe PCIe 4.0 x4 HS SSD4
15mm 2.5-inch hot-swap PCIe 4.0 NVMe SSDs
4XB7A13941BMGDThinkSystem 2.5" U.2 P5520 1.92TB Read Intensive NVMe PCIe 4.0 x4 HS SSD2
4XB7A13942BMGEThinkSystem 2.5" U.2 P5520 3.84TB Read Intensive NVMe PCIe 4.0 x4 HS SSD2
4XB7A13943BNEFThinkSystem 2.5" U.2 P5520 7.68TB Read Intensive NVMe PCIe 4.0 x4 HS SSD2
4XB7A17129BNEGThinkSystem 2.5" U.2 P5620 1.6TB Mixed Use NVMe PCIe 4.0 x4 HS SSD2
4XB7A17130BNEHThinkSystem 2.5" U.2 P5620 3.2TB Mixed Use NVMe PCIe 4.0 x4 HS SSD2
4XB7A17160BMM8ThinkSystem 2.5" U.2 P5800X 1.6TB Write Intensive NVMe PCIe 4.0 x4 HS SSD2
4XB7A13967BNEJThinkSystem 2.5" U.3 7450 MAX 1.6TB Mixed Use NVMe PCIe 4.0 x4 HS SSD2
4XB7A13970BNEYThinkSystem 2.5" U.3 7450 MAX 3.2TB Mixed Use NVMe PCIe 4.0 x4 HS SSD2
4XB7A79647BNF2ThinkSystem 2.5" U.3 7450 PRO 1.92TB Read Intensive NVMe PCIe 4.0 x4 HS SSD2
4XB7A79648BNF5ThinkSystem 2.5" U.3 7450 PRO 3.84TB Read Intensive NVMe PCIe 4.0 x4 HS SSD2
4XB7A79649BNF4ThinkSystem 2.5" U.3 7450 PRO 7.68TB Read Intensive NVMe PCIe 4.0 x4 HS SSD2
2280 NVMe M.2 drives
4XB7A82674BQUJThinkSystem M.2 7450 PRO 960GB Read Intensive NVMe PCIe 4.0 x4 NHS SSD (with Heatsink)2
4XB7A83139BS46ThinkSystem M.2 7450 PRO 480GB Read Intensive NVMe PCIe 4.0 x4 NHS SSD (with Heatsink)2
M.2 N-30m2 Read Intensive NVMe PCIe 3.0 x4 NHS SSD
4XB7A90722BYLNThinkSystem M.2 N-30m2 1.92TB Read Intensive NVMe PCIe 3.0 x4 NHS SSD (Industrial)2
4XB7A90721BYLMThinkSystem M.2 N-30m2 960GB Read Intensive NVMe PCIe 3.0 x4 NHS SSD (Industrial)2
4XB7A90720BYLLThinkSystem M.2 N-30m2 480GB Read Intensive NVMe PCIe 3.0 x4 NHS SSD (Industrial)2

Optical drive

The server supports the external USB optical drive listed in the following table.

Table 9. External optical drive
Part numberFeature codeDescription
7XA7A05926AVV8ThinkSystem External USB DVD RW Optical Disk Drive

The drive is based on the Lenovo Slim DVD Burner DB65 drive and supports the following formats: DVD-RAM, DVD-RW, DVD+RW, DVD+R, DVD-R, DVD-ROM, DVD-R DL, CD-RW, CD-R, CD-ROM.

Network Modules

The network ports on the front of the SE350 V2are provided by a Network Module, a board that plugs into the system board by a dedicated connector. See the Internal view for the location of the connector. The Network Modules are listed in the following table.

Table 10. Network Modules
Part numberFeature codeDescription
CTO onlyBS3U

SE350 V2 1Gbx4 I/O Module board

CTO onlyBS3T

SE350 V2 25G/10G IO Module board

The Network Modules have the following characteristics:

  • 1GbE I/O module board
    • Two USB 3.2 Gen 1 Type-A connectors
    • USB 3.2 Gen 1 Type-C connector (supporting display)
    • USB 2.0 Gen 1 Type-C connector with Lenovo XClarity Controller (XCC) management
    • One XCC system management port (1GbE RJ-45)
    • Four 1GbE RJ-45 connectors
    • Two 2.5GbE RJ-45 connectors
    • 2.5G RJ45 ports support 1G speed with LED normal behavior
    • Note:
      • 2.5Gb RJ45 ports support 100Mbps data transfer, but link speed LED keep dark, do not support 10Mbps.
      • 1Gb RJ45 port support 100M bps if link peer does not force speed on 100Mbps since Icelake D doesn’t support 100M half-duplex and link LED is always green status, while ACT LED keeps green and wont blinking when transferring data; do not support 10Mbps
  • 10/25GbE SFP28 I/O module board
    • Two USB 3.2 Gen 1 Type-A connectors
    • USB 3.2 Gen 1 Type-C connector (supporting display)
    • USB 2.0 Gen 1 Type-C connector with Lenovo XClarity Controller (XCC) management
    • One XCC system management port (1GbE RJ-45)
    • Four 10/25GbE SFP28 connectors
    • Two 2.5GbE RJ-45 connectors
    • No support for10 Mbps / 100 Mbps speeds

Note: When the shipping bracket is installed, the front operator panel is not accessible.

The network modules are shown in the following figure.


Figure 10. Ports of the available Network Modules

The block diagrams of the Network Modules are shown in the System architecture section.

The specifications of the connections in the two Wired Network Modules are as follows:

  • Front IO with 25G/10G x4
    • Front Op-Panel
    • 4x 10Gb/25Gb SFP28 (SFP28 from CPU embedded LAN)
    • 2x 2.5Gb RJ45 (RJ45 from intel I226)
    • 1x XCC Management Port (dedicate RJ45 Management port for XCC)
    • 1x USB Type-C port (USB Management port for XCC)
    • 1x USB Type-C port (USB 3.0/2.0 from CPU for display)
    • 2x USB Type-A port (USB 3.0/2.0 from CPU)
  • Front IO with 1G x4
    • Front Op-Panel
    • 4x 1GbRJ45 (RJ45 from CPU embedded LAN)
    • 2x 2.5Gb RJ45 (RJ45 from intel I226)
    • 1x XCC Management Port (dedicated RJ45 Management port for XCC)
    • 1x USB Type-C port (USB Management port for XCC)
    • 1x USB Type-C port (USB 3.0/2.0 from CPU for display)
    • 2x USB Type-A port (USB 3.0/2.0 from CPU)

TheSFP28 ports in theWired Network Module support the transceivers listed in the following table.

Table 11. Transceivers for Network Modules
Part numberFeature codeDescription
10Gb transceivers
4TC7A78615BNDRThinkSystem Accelink 10G SR SFP+ Ethernet transceiver
46C34475053SFP+ SR Transceiver
00MY034ATTJLenovo Dual Rate 1G/10GB SFP Transceiver
25Gb transceivers
4M27A67041BFH2Lenovo 25Gb SR SFP28Ethernet Transceiver
7G17A03537AV1BLenovo Dual Rate 10G/25G SR SFP28 Transceiver

The SFP28ports of the Network Modules support the following fiber optic cables and direct-attach copper (DAC) cables.

Table 12. Optical cables and DAC cables
Part numberFeature codeDescription
LC-LC OM3 Fiber Optic Cables (these cables require a 10 GbE SFP+ SR transceiver)
00MN499ASR5Lenovo 0.5m LC-LC OM3 MMF Cable
00MN502ASR6Lenovo 1m LC-LC OM3 MMF Cable
00MN505ASR7Lenovo 3m LC-LC OM3 MMF Cable
00MN508ASR8Lenovo 5m LC-LC OM3 MMF Cable
00MN511ASR9Lenovo 10m LC-LC OM3 MMF Cable
00MN514ASRALenovo 15m LC-LC OM3 MMF Cable
00MN517ASRBLenovo 25m LC-LC OM3 MMF Cable
00MN520ASRCLenovo 30m LC-LC OM3 MMF Cable
OM4 LC to LC Cables (these cables require a transceiver)
4Z57A10845B2P9Lenovo 0.5m LC-LC OM4 MMF Cable
4Z57A10846B2PALenovo 1m LC-LC OM4 MMF Cable
4Z57A10847B2PBLenovo 3m LC-LC OM4 MMF Cable
4Z57A10848B2PCLenovo 5m LC-LC OM4 MMF Cable
4Z57A10849B2PDLenovo 10m LC-LC OM4 MMF Cable
4Z57A10850B2PELenovo 15m LC-LC OM4 MMF Cable
4Z57A10851B2PFLenovo 25m LC-LC OM4 MMF Cable
4Z57A10852B2PGLenovo 30m LC-LC OM4 MMF Cable
SFP+ 10Gb Passive DAC Cables
00AY764A51N1.5m Passive DAC SFP+ Cable
00AY765A51P2m Passive DAC SFP+ Cable
90Y9430A1PJ3m Passive DAC SFP+ Cable
25G SFP28 Active Optical Cables
7Z57A03541AV1FLenovo 3m 25G SFP28 Active Optical Cable
7Z57A03542AV1GLenovo 5m 25G SFP28 Active Optical Cable
7Z57A03543AV1HLenovo 10m 25G SFP28 Active Optical Cable
7Z57A03544AV1JLenovo 15m 25G SFP28 Active Optical Cable
7Z57A03545AV1KLenovo 20m 25G SFP28 Active Optical Cable
100G QSFP28Breakout Active Optical Cables
7Z57A03551AV1RLenovo 3m 100G to 4x25G Breakout Active Optical Cable
7Z57A03552AV1SLenovo 5m 100G to 4x25G Breakout Active Optical Cable
7Z57A03553AV1TLenovo 10m 100G to 4x25G Breakout Active Optical Cable
7Z57A03554AV1ULenovo 15m 100G to 4x25G Breakout Active Optical Cable
7Z57A03555AV1VLenovo 20m 100G to 4x25G Breakout Active Optical Cable

The following table lists the direct-attach copper (DAC) cables that are supported in the 25GbE port.

Table 13. Copper cables
Part numberFeature codeDescription
SFP+ 10Gb Passive DAC Cables
00D6288A3RG0.5m Passive DAC SFP+ Cable
90Y9427A1PH1m Passive DAC SFP+ Cable
00AY764A51N1.5m Passive DAC SFP+ Cable
00AY765A51P2m Passive DAC SFP+ Cable
90Y9430A1PJ3m Passive DAC SFP+ Cable
90Y9433A1PK5m Passive DAC SFP+ Cable
00D6151A3RH7m Passive DAC SFP+ Cable
SFP28 25Gb Passive DAC Cables
7Z57A03557AV1WLenovo 1m Passive 25G SFP28 DAC Cable
7Z57A03558AV1XLenovo 3m Passive 25G SFP28 DAC Cable
7Z57A03559AV1YLenovo 5m Passive 25G SFP28 DAC Cable
QSFP28 100G-to-4x25G Breakout Cables
7Z57A03564AV22Lenovo 1m 100G QSFP28 to 4x25G SFP28 Breakout DAC Cable
7Z57A03565AV23Lenovo 3m 100G QSFP28 to 4x25G SFP28 Breakout DAC Cable
7Z57A03566AV24Lenovo 5m 100G QSFP28 to 4x25G SFP28 Breakout DAC Cable

The RJ45 ports of the Network Modules support the following Category 6 (CAT 6) cables.

Table 14. CAT6 cables
Part numberFeature codeDescription
CAT6 Green Cables
00WE123AVFW0.75m CAT6 Green Cable
00WE127AVFX1.0m CAT6 Green Cable
00WE131AVFY1.25m CAT6 Green Cable
00WE135AVFZ1.5m CAT6 Green Cable
00WE139AVG03m CAT6 Green Cable
90Y3715A1MS10m Yellow Cat6 Cable
90Y3718A1MT10m Green Cat6 Cable
90Y3721A1MU10m Blue Cat6 Cable
90Y3724A1MV25m Yellow Cat6 Cable
90Y3727A1MW25m Green Cat6 Cable
90Y3730A1MX25m Blue Cat6 Cable
CAT6 RJ45/RJ45
4X97A83980BRW9Lenovo 750mm Cat6 RJ45 White Cable without Jacket
4X97A83981BRWALenovo 1000mm Cat6 RJ45 White Cable without Jacket
4X97A83982BRWBLenovo 1250mm Cat6 RJ45 White Cable without Jacket
4X97A83983BRWCLenovo 1500mm Cat6 RJ45 White Cable without Jacket
4X97A83984BRWDLenovo 3000mm Cat6 RJ45 White Cable without Jacket

Network adapters

The SE350 V2 does not support additional network adapters. There is no PCIe slot available.

GPU adapters

The SE350 V2does not support any graphics processing units (GPUs). There is no PCIe slot available.

Cooling

The SE350 V2 server has three 40 mm non-hot-swap fans. All three are standard and support N+1 redundancy.

Power supplies

The SE350 V2 supports three type of power input path as following components and options:

  • External AC Power Supply (230V/115V) (5°C to 40°C)
    • Details regarding the use of AC adapters:
      • One or two AC adapters are supported.
      • When two AC adapters are connected, the second AC adapter is redundant.
      • In case of failure of an AC adapter, system will throttle if power budget is above adapter capacity.
      • To connect AC Adapters to system directly a bridge cable is required.
      • AC Adapters do not include a line cord. See the next section for available power cords.
  • Direct DC Power Connection (12-48V)(0°C to 55°C)
    • Details regarding the use of DC power:
      • One or two DC power input source are supported.
      • When two DC power input are connected, the second DC input is redundant.
      • In case of failure of DC input, system will throttle if power budget is above DC input capacity.
      • DC Terminal block cable for DC power source connection with system.
  • Internal AC Power Supply (230V/115V) (0°C to 55°C)
    • Details regarding the use of AC power:
      • One AC power input source is supported only.
      • Internal AC Power supply doesnot support power redundancy or hot swap.
      • Power supply do not include a line cord. See the next section for available power cords.

Ordering information is listed in the following table.

Table 15. Power options
Part numberFeature codeDescriptionMaximum
supported
External AC Power Supply (230V/115V)
CTO onlyBU98ThinkEdge SE350 V2 12-48V DC Power Module Board1
CTO onlyBS4AThinkEdge SE350 V2 DC Power Input Board1
4X27A88607BW2KThinkEdge 300W 230V/115V External Power Supply2
4X97A88737BW2IThinkEdge SE350 V2 External 300W Bridge Cable2
Direct DC Power Connection (12-48V)
CTO onlyBU98ThinkEdge SE350 V2 12-48V DC Power Module Board1
CTO onlyBS4AThinkEdge SE350 V2 DC Power Input Board1
4L67A91004BS4CThinkEdge SE350 V2 External DC Terminal Block Cable2
Internal AC Power Supply (230V/115V)
CTO onlyBUGPThinkEdge SE350 V2 AC Power Input Board1
CTO onlyBWK7ThinkEdge SE350 V2 500W 230V/115V Non-Hot Swap Power Supply1

Power cords

Line cords and rack power cables can be ordered as listed in the following table.

Table 16. Power cords
Part numberFeature codeDescription
Power cord for AC adapters
39Y793062222.8m, 10A/250V, C13 to IRAM 2073 (Argentina) Line Cord
81Y238464924.3m 10A/220V, C13 to IRAM 2073 (Argentina) Line Cord
39Y792462112.8m, 10A/250V, C13 to AS/NZ 3112 (Australia/NZ) Line Cord
81Y238365744.3m, 10A/230V, C13 to AS/NZS 3112 (Aus/NZ) Line Cord
69Y198865322.8m, 10A/250V, C13 to NBR 14136 (Brazil) Line Cord
81Y238764044.3m, 10A/250V, C13 - 2P+Gnd (Brazil) Line Cord
39Y792862102.8m, 220-240V, C13 to GB 2099.1 (China) Line Cord
81Y237865804.3m, 10A/220V, C13 to GB 2099.1 (China) Line Cord
39Y791862132.8m, 10A/250V, C13 to DK2-5a (Denmark) Line Cord
81Y238265754.3m, 10A/230V, C13 to DK2-5a (Denmark) Line Cord
39Y791762122.8m, 10A/230V, C13 to CEE7-VII (Europe) Line Cord
81Y237665724.3m, 10A/230V, C13 to CEE7-VII (Europe) Line Cord
39Y792762692.8m, 10A/250V, C13(2P+Gnd) (India) Line Cord
81Y238665674.3m, 10A/240V, C13 to IS 6538 (India) Line Cord
39Y792062182.8m, 10A/250V, C13 to SI 32 (Israel) Line Cord
81Y238165794.3m, 10A/230V, C13 to SI 32 (Israel) Line Cord
39Y792162172.8m, 220-240V, C13 to CEI 23-16 (Italy/Chile) Line Cord
81Y238064934.3m, 10A/230V, C13 to CEI 23-16 (Italy/Chile) Line Cord
46M2593A1RE2.8m, 12A/125V, C13 to JIS C-8303 (Japan) Line Cord
4L67A0835765332.8m, 200V, C13 to JIS C-8303 (Japan) Line Cord
39Y792663354.3m, 12A/100V, C13 to JIS C-8303 (Japan) Line Cord
4L67A0836264954.3m, 12A/200V, C13 to JIS C-8303 (Japan) Line Cord
39Y792262142.8m, 10A/250V, C13 to SABS 164 (S Africa) Line Cord
81Y237965764.3m, 10A/230V, C13 to SABS 164 (South Africa) Line Cord
39Y792562192.8m, 220-240V, C13 to KETI (S Korea) Line Cord
81Y238564944.3m, 12A/220V, C13 to KSC 8305 (S. Korea) Line Cord
39Y791962162.8m, 10A/250V, C13 to SEV 1011-S24507 (Swiss) Line Cord
81Y239065784.3m, 10A/230V, C13 to SEV 1011-S24507 (Sws) Line Cord
23R715863862.8m, 10A/125V, C13 to CNS 10917-3 (Taiwan) Line Cord
81Y237563172.8m, 10A/240V, C13 to CNS 10917-3 (Taiwan) Line Cord
4L67A08363AX8B4.3m, 10A 125V, C13 to CNS 10917 (Taiwan) Line Cord
81Y238965314.3m, 10A/250V, C13 to 76 CNS 10917-3 (Taiwan) Line Cord
39Y792362152.8m, 10A/250V, C13 to BS 1363/A (UK) Line Cord
81Y237765774.3m, 10A/230V, C13 to BS 1363/A (UK) Line Cord
90Y301663132.8m, 10A/120V, C13 to NEMA 5-15P (US) Line Cord
4L67A0835963704.3m, 10A/125V, C13 to NEMA 5-15P (US) Line Cord
4L67A0836163734.3m, 10A/250V, C13 to NEMA 6-15P (US) Line Cord
46M2592A1RF2.8m, 10A/250V, C13 to NEMA 6-15P Line Cord
Rack jumper cables for AC adapters
SL67B08593BPHZ0.5m, 10A/100-250V, C13 to C14 Jumper Cord
00Y3043A4VP1.0m, C13 to C14 Jumper Cord, Rack Power Cable
4L67A08365B0N42.0m, 10A/100-250V, C13 to C14 Jumper Cord
4L67A0836663112.8m, 10A/100-250V, C13 to C14 Jumper Cord
39Y793762011.5m, 10A/100-250V, C13 to IEC 320-C14 Rack Power Cable
39Y793262634.3m, 10A/100-250V, C13 to IEC 320-C14 Rack Power Cable
Rack Y-type jumper cables for AC adapters
00Y3046A4VQ1.345m, 2X C13 to C14 Jumper Cord, Rack Power Cable
00Y3047A4VR2.054m, 2X C13 to C14 Jumper Cord, Rack Power Cable

Systems management

The SE350 V2 contains an integrated service processor, XClarity Controller 2 (XCC2), which provides advanced control, monitoring, and alerting functions. The XCC2 is based on the AST2600baseboard management controller (BMC) using a dual-core ARM Cortex A9 service processor.

Topics in this section:

  • Local management
  • Lenovo XClarity Mobile
  • Remote management
  • XCC2 Platinum
  • Lenovo XClarity Provisioning Manager
  • Lenovo XClarity Administrator
  • Lenovo XClarity Essentials
  • Lenovo XClarity Energy Manager
  • Lenovo Capacity Planner

Local management

The SE350V2 offers a front operator panel with key LED status indicators, as shown in the following figure.


Figure 11. Front operator panel

The buttons on the front of the server:

  • Power button
  • Identification button - turns on the LED housed within the button as well as passing the signal to the XCC for display remotely in XClarity Administrator
  • NMI reset pinhole - sends a NMI signal to the processor thereby causing a blue-screen trap of the operating system

The LEDs on the front of the server are as follows:

  • Power LED (green) - indicated activation and power status, as follows:
    • Off - Server does not have power applied
    • Fast flash (4 times per second) - Either server has just had power applied and is not ready to be powered on yet, or the server has not been activated yet
    • Slow flash (once per second) - Server is ready to be powered on
    • On solid - Server is powered on
  • Identification LED (blue) - lights when the button is pressed or when the function is activated remotely in XClarity Controller.
  • Security LED - (green) - indicates system security status.
    • Solid on - the server is operating with security enabled
    • Blinking - the server is in lockdown mode. Activate or unlock the system for operation or activation. See activate or unlock system.
    • Off - No security feature is enabled on the server.

The front of the server also houses an information pull-out tab (also known as the network access tag). See Figure 2 for the location. A label on the tab shows the network information (MAC address and other data) to remotely access the XCC service processor.

The SE350 V2 also supports optional connection to local VGA monitor.

Table 17. USB type-C to VGA cable
Part numberFeature codeDescription
4X97A86591BS4EThinkEdge 130mm USB-C to VGA Display Cable

System status with XClarity Mobile

The SE350 V2also supports local systems management using the XClarity Mobile app. The app includes a tethering function where you can connect your Android or iOS device to the server via the micro-USB port on the server.

You will need a mobile device with a supported operating system installed (iOS 12 or later, Android 5.0 or later), plus the USB charging cable that comes with your phone. You will also need the USB type-C to USB type-Acable that ships with the SE350 V2.

The steps to connect the mobile device are as follows:

  1. Connect the mobile device via your USB cable and the supplied USB-to USB type-Ccable to the SE350 V2's USB type-Cport with the management symbol Lenovo ThinkEdge SE350 V2 Server Product Guide (13)
  2. In iOS or Android settings, enable Personal Hotspot or USB Tethering
  3. Launch the Lenovo XClarity Mobile app

Once connected you can see the following information:

  • Server status including error logs (read only, no login required)
  • Server management functions (XClarity login credentials required)

The supported USB cable is listed in the following table.

Table 18. USB type-C to USB type-A cable
Part numberFeature codeDescription
4X97A88620BS4DThinkEdge USB-C to USB-A Console Cable

Remote management

The server offers a dedicated RJ45 port at the rear of the server for remote management via the XClarity Controller management processor. The port supports 10/100/1000 Mbps speeds.

Remote server management is provided through industry-standard interfaces:

  • Intelligent Platform Management Interface (IPMI) Version 2.0
  • Simple Network Management Protocol (SNMP) Version 3 (no SET commands; no SNMP v1)
  • Common Information Model (CIM-XML)
  • Representational State Transfer (REST) support
  • Redfish support (DMTF compliant)
  • Web browser - HTML 5-based browser interface (Java and ActiveX not required) using a responsive design (content optimized for device being used - laptop, tablet, phone) with NLS support

The SE350 V2offers a MicroSD card port on the system board to enable the use of a MicroSD card for additional storage for use with the XCC2 controller. XCC2 can use the storage as a Remote Disc on Card (RDOC) device (up to 32GB of storage). It can also be used to store firmware updates (including N-1 firmware history) for ease of deployment.

Tip: Without a MicroSD card installed, the XCC2 controller will have 100MB of available RDOC storage.

Ordering information for the supported Micro SD card is listed in the following table.

Table 19. MicroSD card
Part numberFeature codeDescription
4X77A77064BNWPThinkSystem MicroSD 32GB Class 10 Flash Memory Card

XCC2 Platinum

The XCC2 service processor in the SE350 V2supports an upgrade to a Platinum level of features. Compared to the XCC functions of ThinkSystem and earlier systems, Platinum adds the same features as Enterprise and Advanced levels in ThinkSystem, plus additional features.

XCC2 Platinum adds the following Enterprise and Advanced functions:

  • Remotely viewing video with graphics resolutions up to 1600x1200 at 75 Hz with up to 23 bits per pixel, regardless of the system state
  • Remotely accessing the server using the keyboard and mouse from a remote client
  • International keyboard mapping support
  • Syslog alerting
  • Redirecting serial console via SSH
  • Component replacement log (Maintenance History log)
  • Access restriction (IP address blocking)
  • Lenovo SED security key management
  • Displaying graphics for real-time and historical power usage data and temperature
  • Boot video capture and crash video capture
  • Virtual console collaboration - Ability for up to 6 remote users to be log into the remote session simultaneously
  • Remote console Java client
  • Mapping the ISO and image files located on the local client as virtual drives for use by the server
  • Mounting the remote ISO and image files via HTTPS, SFTP, CIFS, and NFS
  • Power capping
  • System utilization data and graphic view
  • Single sign on with Lenovo XClarity Administrator
  • Update firmware from a repository
  • License for XClarity Energy Manager

XCC2 Platinum also adds the following features that are new to XCC2:

  • System Guard - Monitor hardware inventory for unexpected component changes, and simply log the event or prevent booting
  • Enterprise Strict Security mode - Enforces CNSA 1.0 level security
  • Neighbor Group - Enables administrators to manage and synchronize configurations and firmware level across multiple servers

Ordering information is listed in the following table. XCC2 Platinum is a software license upgrade - no additional hardware is required.

Table 20. XCC2 Platinum license upgrade
Part numberFeature codeDescription
CTO onlyBRPJXCC Platinum

With XCC Platinum, for CTO orders, you can request that System Guard be enabled in the factory and the first configuration snapshot be recorded. To add this to an order, select feature code listed in the following table. The selection is made in the Security tab of the DCSC configurator.

Table 21. Enable System Guard in the factory (CTO orders)
Feature codeDescription
BUT2Install System Guard

For more information about System Guard, see https://pubs.lenovo.com/xcc2/NN1ia_c_systemguard

Lenovo XClarity Provisioning Manager

Lenovo XClarity Provisioning Manager (LXPM) is a UEFI-based application embedded in ThinkSystem servers and accessible via the F1 key during system boot.

LXPM provides the following functions:

  • Graphical UEFI Setup
  • System inventory information and VPD update
  • System firmware updates (UEFI and XCC)
  • RAID setup wizard
  • OS installation wizard (including unattended OS installation)
  • Diagnostics functions

Lenovo XClarity Administrator

Lenovo XClarity Administrator is a centralized resource management solution designed to reduce complexity, speed response, and enhance the availability of Lenovo systems and solutions. It provides agent-free hardware management for ThinkSystem servers, in addition to ThinkServer, System x, and Flex System servers. The administration dashboard is based on HTML 5 and allows fast location of resources so tasks can be run quickly.

Because Lenovo XClarity Administrator does not require any agent software to be installed on the managed endpoints, there are no CPU cycles spent on agent execution, and no memory is used, which means that up to 1GB of RAM and 1 - 2% CPU usage is saved, compared to a typical managed system where an agent is required.

Lenovo XClarity Administrator is an optional software component for the SE350 V2. The software can be downloaded and used at no charge to discover and monitor the SE350 V2 and to manage firmware upgrades.

If software support is required for Lenovo XClarity Administrator, or premium features such as configuration management and operating system deployment are required, Lenovo XClarity Pro software subscription should be ordered. Lenovo XClarity Pro is licensed on a per managed system basis, that is, each managed Lenovo system requires a license.

The following table lists the Lenovo XClarity software license options.

Table 22. Lenovo XClarity Pro ordering information
Part numberFeature codeDescription
00MT2011339Lenovo XClarity Pro, per Managed Endpoint w/1 Yr SW S&S
00MT2021340Lenovo XClarity Pro, per Managed Endpoint w/3 Yr SW S&S
00MT2031341Lenovo XClarity Pro, per Managed Endpoint w/5 Yr SW S&S
7S0X000HWWSAYVLenovo XClarity Pro, per Managed Endpoint w/6 Yr SW S&S
7S0X000JWWSAYWLenovo XClarity Pro, per Managed Endpoint w/7 Yr SW S&S

Lenovo XClarity Administrator offers the following standard features that are available at no charge:

  • Auto-discovery and monitoring of Lenovo systems
  • Firmware updates and compliance enforcement
  • External alerts and notifications via SNMP traps, syslog remote logging, and e-mail
  • Secure connections to managed endpoints
  • NIST 800-131A or FIPS 140-2 compliant cryptographic standards between the management solution and managed endpoints
  • Integration into existing higher-level management systems such as cloud automation and orchestration tools through REST APIs, providing extensive external visibility and control over hardware resources
  • An intuitive, easy-to-use GUI
  • Scripting with Windows PowerShell, providing command-line visibility and control over hardware resources

Lenovo XClarity Administrator offers the following premium features that require an optional Pro license:

  • Pattern-based configuration management that allows to define configurations once and apply repeatedly without errors when deploying new servers or redeploying existing servers without disrupting the fabric
  • Bare-metal deployment of operating systems and hypervisors to streamline infrastructure provisioning

For more information, refer to the Lenovo XClarity Administrator Product Guide:
http://lenovopress.com/tips1200

Lenovo XClarity Integrators

Lenovo also offers software plug-in modules, Lenovo XClarity Integrators, to manage physical infrastructure from leading external virtualization management software tools including those from Microsoft and VMware.

These integrators are offered at no charge, however if software support is required, a Lenovo XClarityPro software subscription license should be ordered.

Lenovo XClarity Integrators offer the following additional features:

  • Ability to discover, manage, and monitor Lenovo server hardware from VMware vCenter or Microsoft System Center
  • Deployment of firmware updates and configuration patterns to Lenovo x86rack servers and Flex System from the virtualization management tool
  • Non-disruptive server maintenance in clustered environments that reduces workload downtime by dynamically migrating workloads from affected hosts during rolling server updates or reboots
  • Greater service level uptime and assurance in clustered environments during unplanned hardware events by dynamically triggering workload migration from impacted hosts when impending hardware failures are predicted

For more information about all the available Lenovo XClarity Integrators, see the Lenovo XClarity Administrator Product Guide: https://lenovopress.com/tips1200-lenovo-xclarity-administrator

Lenovo XClarity Essentials

Lenovo offers the following XClarity Essentials software tools that can help you set up, use, and maintain the server at no additional cost:

  • Lenovo Essentials OneCLI

    OneCLI is a collection of server management tools that uses a command line interface program to manage firmware, hardware, and operating systems. It provides functions to collect full system health information (including health status), configure system settings, and update system firmware and drivers.

  • Lenovo Essentials UpdateXpress

    The UpdateXpress tool is a standalone GUI application for firmware and device driver updates that enables you to maintain your server firmware and device drivers up-to-date and help you avoid unnecessary server outages. The tool acquires and deploys individual updates and UpdateXpress System Packs (UXSPs) which are integration-tested bundles.

  • Lenovo Essentials Bootable Media Creator

    The Bootable Media Creator (BOMC) tool is used to create bootable media for offline firmware update.

For more information and downloads, visit the Lenovo XClarity Essentials web page:
http://support.lenovo.com/us/en/documents/LNVO-center

Lenovo XClarity Energy Manager

Lenovo XClarity Energy Manager (LXEM) is a power and temperature management solution for data centers. It is an agent-free, web-based console that enables you to monitor and manage power consumption and temperature in your data center through the management console. It enables server density and data center capacity to be increased through the use of power capping.

LXEM is a licensed product. A single-node LXEM license is included with the XClarity Controller Enterprise upgrade as described in the Remote Management section. If your server does not have the XCC Enterprise upgrade, Energy Manager licenses can be ordered as shown in the following table.

Table 23. Lenovo XClarity Energy Manager
Part numberDescription
4L40E51621Lenovo XClarity Energy Manager Node License (1 license needed per server)

For more information about XClarity Energy Manager, see the following resources:

  • Lenovo Support page:
    https://datacentersupport.lenovo.com/us/en/solutions/lnvo-lxem
  • User Guide for XClarity Energy Manager:
    https://pubs.lenovo.com/lxem/

Lenovo Capacity Planner

Lenovo Capacity Planner is a power consumption evaluation tool that enhances data center planning by enabling IT administrators and pre-sales professionals to understand various power characteristics of racks, servers, and other devices. Capacity Planner can dynamically calculate the power consumption, current, British Thermal Unit (BTU), and volt-ampere (VA) rating at the rack level, improving the planning efficiency for large scale deployments.

For more information, refer to the Capacity Planner web page:
http://datacentersupport.lenovo.com/us/en/solutions/lnvo-lcp

Security

The SE350 V2 offers a number of security features, both electronic and physical.


Figure 12. Security features of the SE350 V2

Physical security features:

  • Support for a Kensington lock and cable

    The server has a slot on the side of the server which a customer-supplied Kensington lock and cable can be attached to, to help prevent theft of the server.

  • Intrusion arm/disarm feature

    The Kensington cable slot can also double as an electronic switch to disarm the intrusion switch detection, so that authorized servicing of the hardware can be performed without triggering the security actions. Available as the Anti-Tampering Keylock Kit, CTO only. The kit includes a Kensington lock (without cable) that is attached to the outside of the server.

    Note: This intrusion arm/disarm feature is not supported with the 1U or 2U rack enclosure mounting options, due to physical restrictions with the Kensington lock.

  • Front bezel with key lock

    Optional component that mounts on the front of the server that restricts access to networking connectors on the front of the server. See "mounting options" sectionfor more information.

Electronic security features include:

  • Self-encrypting (SED) on M.2 and 2.5" SSD drives that ensure data is secured when the drives are powered off
  • Administrator password and a power-on password in UEFI
  • Onboard Trusted Platform Module (TPM) supporting TPM 2.0 enables advanced cryptographic functionality in the operating system and applications.
  • For China users, the server has an internal TCM port that supports a Nationz TPM 2.0 module. Available CTO only.

The server is NIST SP 800-147B compliant.

Ordering information for the security components is listed in the following table.

Table 24. Security components
Part numberFeature codeDescription
4XF7A88717BS4J

ThinkEdge SE350 V2 Anti-Tampering Keylock Kit

  • Internal lock mechanism with electronic switch
  • Cable and routing tray
  • Kensington lock with key
CTO onlyB8LEThinkSystem NationZ TPM 2.0 for PRC

System Lockdown Mode

System Lockdown Mode is an optional security feature of the SE350 V2 that ensures that the system is only used by its intended recipient and that all data and applications remains secure.

System Lockdown Mode is an optional feature that can be remotely managed in two ways:

  • ThinkShield Key Vault Portal Managed. This provides a centralised remote management approach, allowing the administrator to remotely managed multiple systems and to register ownership of systems to their company, which reduces the system’s value is stolen.
  • XClarity Controller Managed. This provides remote management level control to an individual system using XCC web interface, OneCLI or Redfish.

To select ThinkShield Key Vault Portal Managed in factory orders, select feature BYBR, as listed in the following table. The default in DCSC is to select XClarity Controller Managed, feature BYBQ.

Table 25. Feature codes to activate System Lockdown mode
Feature codeDescriptionPurpose
BYBRThinkShield Key Vault Portal ManagedSystem Lockdown Mode is enabled in the factory (Activation required on delivery). The server remains secured and in System Lockdown Mode until registered and activated with the ThinkEdge Key Vault Portal. Unauthorized tampering of the server will result in the server being locked down and the data secured, and will remain in this state until reauthenticated with the Key Vault Portal.
BYBQXClarity Controller ManagedDefault choice in DCSC. System Lockdown Mode is not enabled in the factory. Configures the server security to be managed by the XCC2 management processor. Server will boot at first power on and, by default, will not be locked down on any tamper event. You can configure tamper detection in the XCC2 interface if desired. The server can be converted to be managed ThinkShield Key Vault Portal at a later stage if desired (one-way conversion).

If System Lockdown is enabled in the factory, the system will be delivered in system lockdown mode and will require activation before operation. There are three ways the server can be activated:

  • Using a mobile device (iOS or Android) connect to the server to the USB management port on the front of the server and running the ThinkShield Edge Mobile Management app.
  • Connecting the system to the Internet via the XCC management port on the front of the server and accessing the ThinkShield Key Vault Portal from a web browser on another system.
  • In a disconnected mode, where neither a mobile device or an internet connection to the SE350 V2 are available.

For more information, see ThinkEdge Security, available from:
https://lenovopress.lenovo.com/lp1725-thinkedge-security

Converting from XCC Managed to Portal Managed: It ispossible to convert a system from XCC Managed security to ThinkShield Key Vault Portal Managed via the XCC management interface, however the reverse is not possible. Once a server is in ThinkShield Key Vault Portal Managed mode, it cannot be converted back to XClarity Controller Managed.

The SE350 V2 offers a Security LED that indicates the status of the server:

  • LED on: Security is enabled; System is operational.
  • LED blinking: Security is enabled and the server is in lockdown, either due to being delivered from the factory in lockdown mode or has entered lockdown as a result of a tamper event. System must be activated or reactivated before becoming operational.
  • LED off: Security is disabled; System is operational.

SED encryption in factory orders

The SE350 V2 also optionally supports enabling SED drive encryption in the factory using feature BYBS as listed in the following table. This feature enables SED on the selected drives and sets and SED Authentication Key (SED AK).

Tip: SED encryption is a function that is independent of System Lockdown Control.

Table 26. System Lockdown
Feature codeDescriptionPurpose
BYBSSED EnabledEnables SED drive encryption on all factory installed drives and sets an SED Authentication Key (AK).

System Guard

The System Guard feature takes a snapshot of the hardware component inventory as trusted reference, then monitors for any deviation from the reference snapshot.

When deviation occurs, it can report an event to the user, optionally, can also prevent the server from booting into the OS and prompt the user for response.

  • System Guard is only enabled with XCC2 on V3 code
  • Server supports this feature (BUT2) when XCC Platinum enabled only.
  • The System Guard feature is disabled by default

System Guard is a feature of XCC Platinum. Sytem Guard (BUT2) should only be selectable if XCC Platinum (BRPJ) is selected.

Table 27. XCC platinum and System Guard details
Feature codeDescription
BRPJXCC Platinum
BUT2Enable System Guard

Platform Firmware Resiliency - Lenovo ThinkShield

Lenovo's ThinkShield Security is a transparent and comprehensive approach to security that extends to all dimensions of our data center products: from development, to supply chain, and through the entire product lifecycle.

The includes Platform Firmware Resiliency (PFR) hardware Root of Trust (RoT) which enables the system to be NIST SP800-193 compliant. This offering further enhances key platform subsystem protections against unauthorized firmware updates and corruption, to restore firmware to an integral state, and to closely monitor firmware for possible compromise from cyber-attacks.

PFR operates upon the following server components:

  • UEFI image – the low-level server firmware that connects the operating system to the server hardware
  • XCC image – the management “engine” software that controls and reports on the server status separate from the server operating system
  • FPGA image – the code that runs the server’s lowest level hardware controller on the motherboard

The Lenovo Platform Root of Trust Hardware performs the following three main functions:

  • Detection – Measures the firmware and updates for authenticity
  • Recovery – Recovers a corrupted image to a known-safe image
  • Protection – Monitors the system to ensure the known-good firmware is not maliciously written

These enhanced protection capabilities are implemented using a dedicated, discrete security processor whose implementation has been rigorously validated by leading third-party security firms. Security evaluation results and design details are available for customer review – providing unprecedented transparency and assurance.

The SE350 V2 includes support for Secure Boot, a UEFI firmware security feature developed by the UEFI Consortium that ensures only immutable and signed software are loaded during the boot time. The use of Secure Boot helps prevent malicious code from being loaded and helps prevent attacks, such as the installation of rootkits. Lenovo offers the capability to enable secure boot in the factory, to ensure end-to-end protection. Alternatively, Secure Boot can be left disabled in the factory, allowing the customer to enable it themselves at a later point, if desired.

The following table lists the relevant feature code(s).

Table 28. Secure Boot options
Part numberFeature codeDescriptionPurpose
CTO onlyAUK7TPM 2.0 and Secure BootConfigure the system in the factory with Secure Boot enabled.
CTO onlyB0MKEnable TPM 2.0Configure the system without Secure Boot enabled. Customers can enable Secure Boot later if desired.

Tip: If Secure Boot is not enabled in the factory, it can be enabled later by the customer. However once Secure Boot is enabled, it cannot be disabled.

Intel Transparent Supply Chain

Add a layer of protection in your data center and have peace of mind that the server hardware you bring into it is safe authentic and with documented, testable, and provable origin.

Lenovo has one of the world’s best supply chains, as ranked by Gartner Group, backed by extensive and mature supply chain security programs that exceed industry norms and US Government standards. Now we are the first Tier1 manufacturer to offer Intel® Transparent Supply Chain in partnership with Intel, offering you an unprecedented degree of supply chain transparency and assurance.

To enable Intel Transparent Supply Chain for the Intel-based servers in your order, add the following feature code in the DCSC configurator, under the Security tab.

Table 29. Intel Transparent Supply Chain ordering information
Feature codeDescription
BB0PIntel Transparent Supply Chain

For more information on this offering, see the paper Introduction to Intel Transparent Supply Chain on Lenovo ThinkSystem Servers, available from https://lenovopress.com/lp1434-introduction-to-intel-transparent-supply-chain-on-thinksystem-servers.

Mounting options

The SE350 V2 is designed to be used in a variety of locations -- wall, ceiling, DIN-rail, table top -- as well as in a rack mount.

In this section:

  • Mounting components
  • Desktop mount
  • Wall or DINmount
  • Security bezel
  • 1U rack installation
  • Short-depth 2U rack installation
  • Mounting options and power

Mounting components

Many of the mounting options share the same components.

Node sleeve

The node sleeve, shown below, holds the SE350 V2 server when mounted on the wall or connected to DIN rail. The serveristhen slid into the node sleeve and secured with additional thumbscrews.

Figure 13. Node sleeve image

Table 30. Node Sleeve ordering information
Part numberFeature codeDescriptionQuantity
required
4M17A37607B6EZThinkEdge Node Sleeve (VESA mount)1 per server

Desktop mount

Desktop mounting has the server oriented horizontally with self-adhesive rubber pads mounted to its underside.


Figure 14. SE350 V2 with Rubber Feet option

Table 31. Desktop mount components
Part numberFeature codeDescriptionQuantity
required
4M17A37610B6Q3ThinkEdge Rubber Feet (contains 4 rubber pads)
1

Wall or DINmount

When wall, ceiling or DIN mounted, the server must be installed onto a sleeve first. For DIN mount, the optional DIN mount kit is required. Server also supports security bezel placement on the front of the node sleeve to help prevent physical access to the front components.

SE350 V2 supports two types of security bezelsfor each of the two I/O module boards. Bezels include:

  • A lock-and-key mechanism for security also support dust filter with optional (4XF7A86284).
  • Filter cover the backplane area for SSD and the network area to reduce the dust that can enter the server through the front air holes.
  • Security bezel can prevent LAN cable plug or unplug after installed on node sleeve.

Tip: 300W external adapter not supported in Wall / DIN mounting

Table 32. Wall or DIN mount
Part numberFeature codeDescriptionQuantity
required
Wall mount mode
4M17A37607B6EZThinkEdge Node Sleeve1 per server
DIN Rail mount mode
4M17A37607B6EZThinkEdge Node Sleeve1 per server
4M17A37285B87SThinkEdge DIN Mount Kit (Extreme Shock & Vibe)Optional, for DIN rail only, 1 per server
Security Bezel
4B37A86282BS4FThinkEdge SE350 V2 Security Bezel for 10/25GbE I/O ModuleOptional, 1 per server
4B37A86283BS4GThinkEdge SE350 V2 Security Bezel for 1GbE I/O ModuleOptional, 1 per server
4XF7A86284BS4HThinkEdge SE350 V2 Security Bezel Dust FilterOptional, 1 per server

The DIN Rail Kit contains two brackets, as shown in the following figure.


Figure 15. DIN Rail Kit

Security bezel

The securitybezel is an optional component that mounts on the front of the node sleeve to help prevent physical access to the front components of the server. The bezel includes a lock-and-key mechanism for security.The bezelcovers the front slots area and the network area to reduce the dust that can enter the server through the front air holes. For part number and feature code detailrefer to Wall or DIN mount table above.

Tip: The use of the securitybezel requires a node sleeve.

Figure 16. Security Bezel

1U rack installation

Two SE350 V2 servers can be mounted in a 1U space, in a rack server. The components are mounted in the Lenovo ThinkEdge SE350 V2 1U2N Enclosure.
ThinkEdge SE350 V2 1U2N Enclosure have two different enclosure to support three type of power input path. Make sure enclosure and server selection leverage the same power input path for installation.

Notes:

  • Lenovo ThinkEdge SE350 V2 1U2N Enclosureis available in DCSC using CTO base model7DBKCTO1WW
  • The 1U2N Enclosure comes with two node fillers to ensure correct airflow if a node space is not populated

The following figure shows two SE350 V2 servers installed in the 1U2N Enclosure.


Figure 17. Lenovo ThinkEdge SE350 V2 1U2N Enclosure with external adapter

The following figure shows the components used in the 1U rack installation.


Figure 18. Lenovo ThinkEdge SE350 V2 1U2N Enclosure with external adapter components

Tip: The ThinkSystem Friction 2-Post Screw-in Rail Kit (B6H2) with external 300W AC power adaptersis not supported in a 2-post rack.

The following figure shows the 1U short rack.

Figure 19. Lenovo ThinkEdge SE350 V2 1U2N Enclosure with Internal AC Power supplyInput and DC direct

The following table lists the components used in the 1U rack installation.

Tip: The top cover of the SE350 V2 is removed before installing the server in the enclosure.

Table 33. Components for the1U2N Enclosure
Part numberFeature codeDescriptionQuantity
required
Toolless Slide Rail Kit and CMA
CTO/model only*7DBKAVAXCMA (1U)1 per Enclosure
4M17A116837DBKAVAL1U and 2U Slide Rail1 per Enclosure
4XF7A836457DBK BS30ThinkSystem Enclosure Universal Short Rack Rail Kit1 per Enclosure
4M17A371057DBK B6H2ThinkSystem Friction 2-Post Screw-in Rail Kit1 per Enclosure
1U2N Enclosure components
CTO/model only*7DBK BSMCThinkEdge SE350 V2 1U2N Enclosure (DC or External PSU)1 per Enclosure
CTO/model only*7DBK BVGYThinkEdge SE350 V2 1U2N Enclosure (AC)1 per Enclosure
CTO/model only*7DBK B6EEThinkEdge Enclosure AC Adapter Support Bracket1 per Enclosure
4XF7A940427DAM/7DAM BVE5ThinkEdge SE350 V2/SE360 V2 Dust Cover Kit for I/O Ports1 per Enclosure
4XF7A940437DBKBSMLThinkEdge SE350 V2 Enclosure Shipping Bracket1 per Enclosure
4XF7A862867DBK BSMDThinkEdge SE350 V2 Enclosure - Rack Dust Filter1 for each server

* Available via configure-to-order (CTO)

The following figure shows the components included in the Front Shipping Bracket.


Figure 20. 1U2N Enclosure Front Shipping Bracket

The following table summarizes the specifications of the two available rail kits

Table 34. Specifications of 1U and 2U Slide Rail
FeatureSlide Rail Kit
Part number4M17A11683
CMAOptional, CTO/model only* (7DBKAVAX)
Rail length807 mm(31.8 in.)
Rail typeFull-out slide (ball bearing)
Slide travel810 mm (31.9 in.)
Tool-less installationYes
In-rack server maintenanceYes
1U PDU supportYes
0U PDU supportYes
Rack typeIBM and Lenovo 4-post, IEC standard-compliant
Mounting holesSquare or round
Mounting flange thickness2 mm (0.08 in.) –3.3 mm (0.13 in.)
Max distance between front
and rear mounting flanges
864 mm (34.0 in.)

* Available via configure-to-order (CTO)

Short-depth 2U rack installation

Two SE350 V2 servers and the four companion AC Adapter power supplies can also be mounted in a short-depth rack or a 2-post rack. In such a configuration, the servers occupy 2U of rack space, the two servers in 1U and the AC Adapters mounted in the 1U space above. The components are mounted in theLenovo ThinkEdge SE350 V2 2U2N Enclosure, machine type 7DBK.

Note:2U2N enclosure supports SE350 V2 server andexternal 300W PSU adapter only.

Notes:

  • Lenovo ThinkEdge SE350 V2 2U2N Enclosureis available in DCSC using CTO base model7DBKCTO2WW
  • The 2U2N Enclosure comes with two node fillers to ensure correct airflow if a node space is not populated

The following figure shows two SE350 V2 servers installed in the Lenovo ThinkEdge SE350 V2 2U2N Enclosure.


Figure 21. Lenovo ThinkEdge SE350 V2 2U2N Enclosure components (rail in open position)

The following table lists the components used in the 1U rack installation.

Tip: The top cover of the SE350 V2 is removed before installing the server in the enclosure.

Table 35. Components for the 2U2N Enclosure
Part numberFeature codeDescriptionQuantity
required
Rail kit selections (choose 1)
4M17A371057DBK B6H2ThinkSystem Friction 2-Post Screw-in Rail Kit1 per enclosure
4XF7A836457DBK BS30ThinkSystem Enclosure Universal Short Rack Rail Kit1 per enclosure
2U2N Enclosure components
CTO/model only*7DBK BY35ThinkEdge SE350 V2 2U2N Enclosure (External PSU)1 per Enclosure
CTO/model only*7DBK B6EEThinkSystem Enclosure AC Adapter Support Bracket1 per Enclosure
4XF7A940427DAM/7DAM BVE5ThinkEdge SE350 V2/SE360 V2 Dust Cover Kit for I/O Ports1 per Enclosure
4XF7A940437DBKBSMLThinkEdge SE350 V2 Enclosure Shipping Bracket1 per Enclosure
4XF7A862867DBKBSMDThinkEdge SE350 V2 Enclosure - Rack Dust Filter1 for each server

* Available via configure-to-order (CTO)

The following figure shows the components included in the Front Shipping Bracket.


Figure 22. ThinkEdge SE350 V2 Enclosure Shipping Bracket

The following table summarizes the specifications of the two available rail kits

Table 36. Specifications of rail kits for short-depth installations
FeatureShort Rack Rail Kit2-Post Screw-in Rail Kit
Part number4XF7A836454M17A37105
CMANoneNone
Rail length484 mm(19.1 in.)484 mm (19.1 in.)
Rail typeHalf-out slide (friction)Half-out slide (friction)
Slide travel270 mm (10.6 in.)270 mm (10.6 in.)
Tool-less installationYesNo
In-rack server maintenanceNoNo
1U PDU supportYesYes
0U PDU supportYesNot applicable
Rack type14-inch to 24-inch depth2-post,EIA standard-compliant (3-inch to 8-inch)
Mounting holesSquare, round, or threadedSquare, round, or threaded
Mounting flange thickness2 mm (0.08 in.) –3.3 mm (0.13 in.)2 mm (0.08 in.) –3.3 mm (0.13 in.)
Max distance between front
and rear mounting flanges
609 mm (24 in.)Not applicable

For additional information on rack mount installation, see the Configuration Installation Guide:
https://pubs.lenovo.com/se350-v2/install_a_node_to_rack

Mounting options and power

The following table list supported mounting options and their corresponding supported power type.

Table 37. Mounting options and supported power type
Power type / PSUDesktopDIN rail (wall/ceiling)Rack 1U2NRack 2U2N
AC & 300W externalYesNoYesYes
DC onlyYesYesYesNo
AC onlyYesYesYesNo

Operating system support

The SE350 V2 supports the following operating systems:

  • Microsoft Windows Server 2019
  • Microsoft Windows Server 2022
  • Red Hat Enterprise Linux 8.6
  • Red Hat Enterprise Linux 8.8
  • Red Hat Enterprise Linux 9.0
  • Red Hat Enterprise Linux 9.2
  • SUSE Linux Enterprise Server 15 SP4
  • SUSE Linux Enterprise Server 15 SP5
  • SUSE Linux Enterprise Server 15 Xen SP4
  • SUSE Linux Enterprise Server 15 Xen SP5
  • Ubuntu 20.04 LTS 64-bit
  • Ubuntu 22.04 LTS 64-bit
  • VMware ESXi 7.0 U3
  • VMware ESXi 8.0 U1
  • VMware ESXi 8.0 U2

For a complete list of supported, certified and tested operating systems, plus additional details and links to relevant web sites, see the Operating System Interoperability Guide: https://lenovopress.lenovo.com/osig#support=all

For configure-to-order configurations, the server can be preloaded with VMware ESXi on M.2 cards installed in an M.2 Boot Adapter. Ordering information is listed in the following table.

Table 38. VMware ESXi preload
Part numberFeature codeDescription
CTO onlyBMEYVMware ESXi 7.0 U3 (Factory Installed)
CTO onlyBQ8SVMware ESXi 8.0 U1 (Factory Installed)
CTO onlyBYC7VMware ESXi 8.0 U2(Factory Installed)

Hyperconverged infrastructure support

Lenovo ThinkEdge systems can be used in hyperconverged solutions either as part of a Lenovo configured and optimized Lenovo ThinkAgile solution, or as a user-configured system.

Refer to the following links for full details.

VMware vSAN

SE350 V2 supports vSAN OSA. For more information refer to this page:
vSAN Original Storage Architecture (OSA)

Microsoft Azure Stack HCI

SE350 V2 is listed in Microsoft Azure Stack HCI catalog. For more information refer to this page:
https://azurestackhcisolutions.azure.microsoft.com/#/catalog/details/d047fc7e-5df1-43d1-97f5-907f0bc65004

Physical and electrical specifications

Dimensions and weight of the SE350 V2 server:

  • Height 41.7 mm (1.64 in.)
  • Width: 209 mm (8.2 in.)
  • Depth: 384 mm (15.12 in.)
  • Maximum weight: 3.75 kg (8.3 lb)

Dimensions and weight of the 1U2N Enclosure, with external power adapter (4x AC adapter bracket):

  • Height: 43 mm (1.7 in.)
  • Width: 439.2mm (17.3in.)(from EIA bracket to EIA bracket)
  • Depth: 773.1mm (30.44in.)
  • Maximum (with 2 nodes and 4 external power adapters): 16.88 kg (37.2lbs)

Dimensions and weight of the 1U2N Enclosure, with internal power supply:

  • Height: 43 mm (1.7 in.)
  • Width: 439.2mm (17.3in.)(from EIA bracket to EIA bracket)
  • Depth: 476.1mm (18.7in.)
  • Maximum (with 2 nodes and internal power supplies):
    • DC power input: 9.85 kg (21.67 lbs)
    • AC power input: 10.03 kg (22.11 lbs)

Dimensions and weight of the 2U2N Enclosure(with AC adapter bracket):

  • Height: 86.9mm (3.4 in.)
  • Width: 439.2mm (17.3in.)(from EIA bracket to EIA bracket)
  • Depth: 476.1mm (18.74in.)
  • Maximum (with 2 nodes and 4 external power adapters): 16.92 kg (37.30lbs)

The shipping dimensions (cardboard packaging) of the SE350 V2 are as follows:

  • Width: 338 mm (13.3 inches)
  • Height: 179 mm (7.0 inches)
  • Depth: 569 mm (22.4 inches)

The shipping dimensions (cardboard packaging) of the SE350 V2 1U Enclosure are as follows:

  • Width: 587 mm (23.1 inches)
  • Height: 225 mm (8.9 inches)
  • Depth: 998 mm (39.3 inches)

Electrical specifications:

  • Electrical Input - 20V 300W external adapters
    • 100 to 127 (nominal) V AC, 50 Hz or 60 Hz
    • 200 to 240 (nominal) V AC, 50 Hz or 60 Hz
  • Models with DC/DC power module board (output 12V):
    • Dual 12-48V variable DC power source input
    • Up to two 300W (230V/115V) external power adapters
  • Supported external power adapters:
    • ThinkEdge 300W 230V/115V External Power Supply

Operating environment

Summary of the environmental specifications of server. Depending on the model, some features might not be available, or some specifications might not apply.

Topics in this section:

  • Acoustical noise emissions
  • Ambient temperature management
  • Environment
  • Shock and vibration
  • Particulate contamination

Acoustical noise emissions

The server has the following acoustic noise emissions declaration:

  • Sound power level (LWAd):
    • Idling:
      • Minimum: 4.0 bels
      • Typical: 4.0 bels
      • Maximum: 4.0 bels
    • Operating:
      • Minimum: 5.3 bels
      • Typical: 5.8 bels
      • Maximum: 5.8 bels
  • Sound pressure level (LpAm):
    • Idling:
      • Minimum: 26.0 dBA
      • Typical: 26.2 dBA
      • Maximum: 26.2 dBA
    • Operating:
      • Minimum: 39.7 dBA
      • Typical: 44.2 dBA
      • Maximum: 44.2 dBA

Note:

  • These sound levels were measured in controlled acoustical environments according to procedures specified by ISO 7779 and are reported in accordance with ISO 9296. The operating profile is represented by 80% CPU TDP or 70%/30% storage read/write.

  • The declared acoustic noise levels are based on the following configurations, which may change depending on configurations/conditions.
    • Minimum: 1x 65W CPU, 2x 16GB RDIMMs, 1GbEx4 + 2.5GbE I/O module board, 1x NVMe M.2 boot drive, 2x SATA SSDs, DC PMB,SE350 V2Desktop mount.
    • Typical: 1x 80W CPU, 4x 64GB RDIMMs, 25/10GbEx4 + 2.5GbE I/O module board, 2x NVMe M.2 boot drives, 4x NVMe SSDs, DC PMB,SE350 V2Desktop mount.
    • Maximum: 1x 100W CPU, 4x 64GB RDIMMs, 25/10GbEx4 + 2.5GbE I/O module board, 2x NVMe M.2 boot drives, 4x NVMe SSDs, DC PMB,SE350 V2Desktop mount.
  • Government regulations (such as those prescribed by OSHA or European Community Directives) may govern noise level exposure in the workplace and may apply to you and your server installation. The actual sound pressure levels in your installation depend upon a variety of factors, including the number of racks in the installation; the size, materials, and configuration of the room; the noise levels from other equipment; the room ambient temperature, and employee's location in relation to the equipment. Further, compliance with such government regulations depends on a variety of additional factors, including the duration of employees' exposure and whether employees wear hearing protection. Lenovo recommends that you consult with qualified experts in this field to determine whether you are in compliance with the applicable regulations.

Ambient temperature management

Adjust ambient temperature when specific components are installed:

  • Keep the ambient temperature to45°Cor lower when one or more NVMe drives are installed. If the ambient temperature is over 45°C, the server will have performance degradation.
  • Keep the ambient temperature to40°Cor lower when AC adapters are installed.
  • Keep the ambient temperature to30°Cor lower to avoid performance degradation when choosing the rack mount with theSE350 V2 1U2N Enclosure. It is advised that the ambient temperature should be kept under27°Cwhen AC adapters are installed.

For CTO orders, specify the operational temperature requirement and the shock & vibration requirement, by selecting the feature codes listed in the following table. Selecting the higher temperature and shock/vibration values will ensure the correct heat/vibration tolerant components are selected.

Table 39. Environmental requirements for CTO orders
Feature codeDescription
Operational temperature selections
BW2HSystem Operational Temperature 5C to 40C / 41F to 104F
B8ZUSystem Operational Temperature 0C to 55C / 32F to 131F

Environment

ThinkEdge SE350 V2complies with ASHRAE Class A4 specifications. System performance may be impacted when operating temperature is outside AHSARE A4 specification or fan failed condition over30°Cambient temperature.ThinkEdge SE350 V2is supported in the following environment:

  • Air temperature:
    • Operating
      • ASHRAE Class H1: 5°C to 25°C (41°F to 77°F); the maximum ambient temperature decreases by 1°C for every 500 m (1640 ft) increase in altitude above 900 m (2,953 ft).
      • ASHRAE Class A2: 10°C to 35°C (50°F to 95°F); the maximum ambient temperature decreases by 1°C for every 300 m (984 ft) increase in altitude above 900 m (2,953 ft).
      • ASHRAE Class A3: 5°C to 40°C (41°F to 104°F); the maximum ambient temperature decreases by 1°C for every 175 m (574 ft) increase in altitude above 900 m (2,953 ft).
      • ASHRAE Class A4: 5°C to 45°C (41°F to 113°F); the maximum ambient temperature decreases by 1°C for every 125 m (410 ft) increase in altitude above 900 m (2,953 ft).
      • The ambient temperature can be extended to 0°C to 55°C (32°F to 131°F) with the following restrictions of configuration:
        • No AC adapter installed
        • NVMe drives may have performance degradation
    • Server off:0°C to 55°C (32°F to 131°F)
    • Shipping/storage:-40°C to 65°C (-40°F to 149°F)
  • Maximum altitude:3,050 m (10,000 ft)
  • Relative Humidity (non-condensing):
    • Operating:8% to 90%, maximum dew point : 24°C (75.2°F)
    • Shipment/storage:8% to 90%, maximum dew point : 27°C (80.6°F)
    • Non-operating (unpacked) storagecan pass the following condition: 5% to 95% at 38.7°C (101.7°F) maximum dry-bulb temperature for 48 hrs.
  • Particulate contamination
    • Depending on the specific configuration,SE350 V2supports a dust filter installed at the front of the enclosure. The dust filter has a Minimum Efficiency Rating Value (MERV) of 5, per ASHRAE 52.2-2017 / 80% Average Arrestance per ASHRAE 52.1-1992.

Note:Airborne particulates and reactive gases acting alone or in combination with other environmental factors such as humidity or temperature might pose a risk to the server. For information about the limits for particulates and gases, seeParticulate contamination.

Shock and vibration

The following information is a summary of the shock and vibration specifications of the server. Depending on the model, some features might not be available, or some specifications might not apply.

Table 40. Shock and vibration specifications
Mounting typeShock (when the server is in operation)Shock (when the server is not in operation, such as in shipping)Vibration (when the server is in operation)Vibration (when the server is not in operation, such as in shipping)
Desktop mount (standing alone)

Half-sine wave, 15G 11ms

Trapezoidal wave, 50G 180 inch/sec

5-100 Hz, 0.15 Grms, 30 mins

2-200 Hz, 1.04 Grms, 15 mins

Rack mount (1U2N and 2U2N)

Half-sine wave, 15G 3ms

  • Free-fall drop height: 100mm
  • Equivalent shock: 70 inch/sec, 2-3 ms

5-500 Hz, 0.21 Grms, 15mins

2-200Hz, 0.8 Grms, 15mins

DIN-rail mountHalf-sine wave, 15G 11msNot applicable5-100 Hz, 0.15 Grms, 30 minsNot applicable
Wall mount
  • All configurations:
    • Half-sine wave, 40G 6ms
    • Half-sine wave, 30G 11ms
  • Configurations with 7mm drives:
    • Half-sine wave, 30G 18ms
Not applicable
  • 1.91 Grms, 10-500 Hz, 30 mins
  • 1.04 Grms, 10-500 Hz, 1 hr
Not applicable
Ceiling mountNot applicableNot applicable
  • 1.91 Grms, 10-500z, 30 mins
  • 1.04 Grms, 10-500z, 1 hr
Not applicable

The following table indicates what environmental conditions (ambient temperature) are supported with SSDdrives.

Table 41. Drive support based on environmental selections (ambient temperature)
Part numberDescription0°C to 35°C36°C to 40°C41°C to 45°C46°C to 50°C51°C to 55°C
7mm SATA SSD - Intel S4520
4XB7A17106ThinkSystem 7mm S4520 240GB Read Intensive SATA 6Gb HS SSDYesYesYesYesYes
4XB7A17107ThinkSystem 7mm S4520 480GB Read Intensive SATA 6Gb HS SSDYesYesYesYesYes
4XB7A17108ThinkSystem 7mm S4520 960GB Read Intensive SATA 6Gb HS SSDYesYesYesYesYes
4XB7A78622ThinkSystem 7mm S4520 1.92TB Read Intensive SATA 6Gb HS SSDYesYesYesYesYes
4XB7A78623ThinkSystem 7mm S4520 3.84TB Read Intensive SATA 6Gb HS SSDYesYesYesYesYes
4XB7A78624ThinkSystem 7mm S4520 7.68TB Read Intensive SATA 6Gb HS SSDYesYesYesYesYes
7mm SATA SSD - Micron 5400
4XB7A82264ThinkSystem 7mm 5400 PRO 240GB Read Intensive SATA 6Gb HS SSDYesYesYesYesYes
4XB7A82265ThinkSystem 7mm 5400 PRO 480GB Read Intensive SATA 6Gb HS SSDYesYesYesYesYes
4XB7A82266ThinkSystem 7mm 5400 PRO 960GB Read Intensive SATA 6Gb HS SSDYesYesYesYesYes
4XB7A82267ThinkSystem 7mm 5400 PRO 1.92TB Read Intensive SATA 6Gb HS SSDYesYesYesYesYes
4XB7A82268ThinkSystem 7mm 5400 PRO 3.84TB Read Intensive SATA 6Gb HS SSDYesYesYesYesYes
4XB7A82269ThinkSystem 7mm 5400 PRO 7.68TB Read Intensive SATA 6Gb HS SSDYesYesYesYesYes
7mm NVMe SSD - Micron 7450
4XB7A82853ThinkSystem 7mm U.3 7450 PRO 960GB Read Intensive NVMe PCIe 4.0 x4 HS SSDYesYesYesYesYes
4XB7A82855ThinkSystem 7mm U.3 7450 PRO 1.92TB Read Intensive NVMe PCIe 4.0 x4 HS SSDYesYesYesYesYes
4XB7A82856ThinkSystem 7mm U.3 7450 PRO 3.84TB Read Intensive NVMe PCIe 4.0 x4 HS SSDYesYesYesYesYes
4XB7A82851ThinkSystem 7mm U.3 7450 MAX 800GB Mixed Use NVMe PCIe 4.0 x4 HS SSDYesYesYesYesYes
15mm NVMe SSD - Micron 7450
4XB7A79647ThinkSystem 2.5" U.3 7450 PRO 1.92TB Read Intensive NVMe PCIe 4.0 x4 HS SSDYesYesYesYes†Yes†
4XB7A79648ThinkSystem 2.5" U.3 7450 PRO 3.84TB Read Intensive NVMe PCIe 4.0 x4 HS SSDYesYesYesYes†Yes†
4XB7A79649ThinkSystem 2.5" U.3 7450 PRO 7.68TB Read Intensive NVMe PCIe 4.0 x4 HS SSDYesYesYesYes†Yes†
4XB7A13967ThinkSystem 2.5” U.3 7450 MAX 1.6TB Mixed Use NVMe PCIe 4.0 x4 HS SSDYesYesYesYes†Yes†
4XB7A13970ThinkSystem 2.5” U.3 7450 MAX 3.2TB Mixed Use NVMe PCIe 4.0 x4 HS SSDYesYesYesYes†Yes†
15mm NVMe SSD - Intel P5520/P5620
4XB7A17129ThinkSystem 2.5” U.2 P5620 1.6TB Mixed Use Mainstream NVMe PCIe 4.0 x4 HS SSDYesYesYesYes†Yes†
4XB7A17130ThinkSystem 2.5” U.2 P5620 3.2TB Mixed Use Mainstream NVMe PCIe 4.0 x4 HS SSDYesYesYesYes†Yes†
4XB7A17160ThinkSystem 2.5” U.2 P5800X 1.6TB Write Intensive NVMe PCIe 4.0 x4 HS SSDYesYesYesYes†Yes†
4XB7A13941ThinkSystem 2.5” U.2 P5520 1.92TB Read Intensive NVMe PCIe 4.0 x4 HS SSDYesYesYesYes†Yes†
4XB7A13942ThinkSystem 2.5” U.2 P5520 3.84TB Read Intensive NVMe PCIe 4.0 x4 HS SSDYesYesYesYes†Yes†
4XB7A13943ThinkSystem 2.5” U.2 P5520 7.68TB Read Intensive NVMe PCIe 4.0 x4 HS SSDYesYesYesYes†Yes†
M.2 NVMe SSD - Micron 7450
4XB7A83139ThinkSystem M.2 7450 PRO 480GB Read Intensive NVMe PCIe 4.0 x4 NHS SSD (with Heatsink)YesYesYesYesYes
4XB7A82674ThinkSystem M.2 7450 PRO 960GB Read Intensive NVMe PCIe 4.0 x4 NHS SSD (with Heatsink)YesYesYesYesYes
M.2 NVMe SSD - Swissbit N-30m2
4XB7A90720ThinkSystem M.2 N-30m2 480GB Read Intensive NVMe PCIe 4.0 x4 NHS SSD (Industrial)YesYesYesYesYes
4XB7A90721ThinkSystem M.2 N-30m2 960GB Read Intensive NVMe PCIe 4.0 x4 NHS SSD (Industrial)YesYesYesYesYes
4XB7A90722ThinkSystem M.2 N-30m2 1.92TB Read Intensive NVMe PCIe 4.0 x4 NHS SSD (Industrial)YesYesYesYesYes

† Performance might slightly decrease with this temperature region

Particulate contamination

Depending on the specific configuration,SE350 V2 supports a dust filter installed at the front of the enclosure. The dust filter has a Minimum Efficiency Rating Value (MERV) of 5, per ASHRAE 52.2-2017 / 80% Average Arrestance per ASHRAE 52.1-1992.

Attention:Airborne particulates (including metal flakes or particles) and reactive gases acting alone or in combination with other environmental factors such as humidity or temperature might pose a risk to the device that is described in this document.

Risks that are posed by the presence of excessive particulate levels or concentrations of harmful gases include damage that might cause the device to malfunction or cease functioning altogether. This specification sets forth limits for particulates and gases that are intended to avoid such damage. The limits must not be viewed or used as definitive limits, because numerous other factors, such as temperature or moisture content of the air, can influence the impact of particulates or environmental corrosives and gaseous contaminant transfer. In the absence of specific limits that are set forth in this document, you must implement practices that maintain particulate and gas levels that are consistent with the protection of human health and safety. If Lenovo determines that the levels of particulates or gases in your environment have caused damage to the device, Lenovo may condition provision of repair or replacement of devices or parts on implementation of appropriate remedial measures to mitigate such environmental contamination. Implementation of such remedial measures is a customer responsibility.

Table 42. Limits for particulates and gases.
ContaminantLimits
Reactive gases

Severity level G1 as per ANSI/ISA 71.04-19851:

  • The copper reactivity level shall be less than 200 Angstroms per month (Å/month ≈ 0.0035 μg/cm2-hour weight gain).2
  • The silver reactivity level shall be less than 200 Angstroms per month (Å/month ≈ 0.0035 μg/cm2-hour weight gain).3
  • The reactive monitoring of gaseous corrosivity must be conducted approximately 5 cm (2 in.) in front of the rack on the air inlet side at one-quarter and three-quarter frame height off the floor or where the air velocity is much higher.

Airborne particulates

Data centers must meet the cleanliness level of ISO 14644-1 class 8.

For data centers without airside economizer, the ISO 14644-1 class 8 cleanliness might be met by choosing one of the following filtration methods:

  • The room air might be continuously filtered with MERV 8 filters.
  • Air entering a data center might be filtered with MERV 11 or preferably MERV 13 filters.

For data centers with airside economizers, the choice of filters to achieve ISO class 8 cleanliness depends on the specific conditions present at that data center.

  • The deliquescent relative humidity of the particulate contamination should be more than 60% RH.4
  • Data centers must be free of zinc whiskers.5

Notes:

1ANSI/ISA-71.04-1985.Environmental conditions for process measurement and control systems: Airborne contaminants. Instrument Society of America, Research Triangle Park, North Carolina, U.S.A.

2The derivation of the equivalence between the rate of copper corrosion growth in the thickness of the corrosion product in Å/month and the rate of weight gain assumes that Cu2S and Cu2O grow in equal proportions

.3The derivation of the equivalence between the rate of silver corrosion growth in the thickness of the corrosion product in Å/month and the rate of weight gain assumes that Ag2S is the only corrosion product.

4The deliquescent relative humidity of particulate contamination is the relative humidity at which the dust absorbs enough water to become wet and promote ionic conduction.

5Surface debris is randomly collected from 10 areas of the data center on a 1.5 cm diameter disk of sticky electrically conductive tape on a metal stub. If examination of the sticky tape in a scanning electron microscope reveals no zinc whiskers, the data center is considered free of zinc whiskers.

Table 43. Environmental requirements for CTO orders
Feature codeDescription
Operational temperature selections
B8ZUSystem Operational Temperature 0C to 55C / 32F to 131F

Warranty and Support

The ThinkEdge SE350 V2has 3-year warranty based on the machine type of the system:

  • 7DA9 - 3 year warranty

ThinkEdge SE350 V2 1U2N Enclosure Lenovo and ThinkEdge SE350 V2 2U2N Enclosurehave the following warranty:

  • 7DBK - 3 year warranty

The standard warranty terms are customer-replaceable unit (CRU) and onsite (for field-replaceable units FRUs only) with standard call center support during normal business hours and 9x5 Next Business Day Parts Delivered.

Lenovo’s additional support services provide a sophisticated, unified support structure for your data center, with an experience consistently ranked number one in customer satisfaction worldwide. Available offerings include:

  • Premier Support

    Premier Support provides a Lenovo-owned customer experience and delivers direct access to technicians skilled in hardware, software, and advanced troubleshooting, in addition to the following:

    • Direct technician-to-technician access through a dedicated phone line
    • 24x7x365 remote support
    • Single point of contact service
    • End to end case management
    • Third-party collaborative software support
    • Online case tools and live chat support
    • On-demand remote system analysis
  • Warranty Upgrade (Preconfigured Support)

    Services are available to meet the on-site response time targets that match the criticality of your systems.

    • 3, 4, or 5 years of service coverage
    • 1-year or 2-year post-warranty extensions
    • Foundation Service: 9x5 service coverage with next business day onsite response. YourDrive YourData is an optional extra (see below).
    • Essential Service: 24x7 service coverage with 4-hour onsite response or 24-hour committed repair (available only in select markets). Bundled with YourDrive YourData.
    • Advanced Service: 24x7 service coverage with 2-hour onsite response or 6-hour committed repair (available only in select markets). Bundled with YourDrive YourData.
  • Managed Services

    Lenovo Managed Services provides continuous 24x7 remote monitoring (plus 24x7 call center availability) and proactive management of your data center using state-of-the-art tools, systems, and practices by a team of highly skilled and experienced Lenovo services professionals.

    Quarterly reviews check error logs, verify firmware & OS device driver levels, and software as needed. We’ll also maintain records of latest patches, critical updates, and firmware levels, to ensure you systems are providing business value through optimized performance.

  • Technical Account Management (TAM)

    A Lenovo Technical Account Manager helps you optimize the operation of your data center based on a deep understanding of your business. You gain direct access to your Lenovo TAM, who serves as your single point of contact to expedite service requests, provide status updates, and furnish reports to track incidents over time. In addition, your TAM will help proactively make service recommendations and manage your service relationship with Lenovo to make certain your needs are met.

  • Enterprise Server Software Support

    Enterprise Software Support is an additional support service providing customers with software support on Microsoft, RedHat, SUSE, and VMware applications and systems. Around the clock availability for critical problems plus unlimited calls and incidents helps customers address challenges fast, without incremental costs. Support staff can answer troubleshooting and diagnostic questions, address product comparability and interoperability issues, isolate causes of problems, report defects to software vendors, and more.

  • YourDrive YourData

    Lenovo’s YourDrive YourData is a multi-drive retention offering that ensures your data is always under your control, regardless of the number of drives that are installed in your Lenovo server. In the unlikely event of a drive failure, you retain possession of your drive while Lenovo replaces the failed drive part. Your data stays safely on your premises, in your hands. The YourDrive YourData service can be purchased in convenient bundles and is optional with Foundation Service. It is bundled with Essential Service and Advanced Service.

  • Health Check

    Having a trusted partner who can perform regular and detailed health checks is central to maintaining efficiency and ensuring that your systems and business are always running at their best. Health Check supports Lenovo-branded server, storage, and networking devices, as well as select Lenovo-supported products from other vendors that are sold by Lenovo or a Lenovo-Authorized Reseller.

Examples of region-specific warranty terms are second or longer business day parts delivery or parts-only base warranty.

If warranty terms and conditions include onsite labor for repair or replacement of parts, Lenovo will dispatch a service technician to the customer site to perform the replacement. Onsite labor under base warranty is limited to labor for replacement of parts that have been determined to be field-replaceable units (FRUs). Parts that are determined to be customer-replaceable units (CRUs) do not include onsite labor under base warranty.

If warranty terms include parts-only base warranty, Lenovo is responsible for delivering only replacement parts that are under base warranty (including FRUs) that will be sent to a requested location for self-service. Parts-only service does not include a service technician being dispatched onsite. Parts must be changed at customer’s own cost and labor and defective parts must be returned following the instructions supplied with the spare parts.

Lenovo Service offerings are region-specific. Not all preconfigured support and upgrade options are available in every region. For information about Lenovo service upgrade offerings that are available in your region, refer to the following resources:

  • Service part numbers in Lenovo Data Center Solution Configurator (DCSC):
    http://dcsc.lenovo.com/#/services
  • Lenovo Services Availability Locator
    http://lenovolocator.com/

For service definitions, region-specific details, and service limitations, please refer to the following documents:

  • Lenovo Statement of Limited Warranty for Infrastructure Solutions Group (ISG) Servers and System Storage
    http://pcsupport.lenovo.com/us/en/solutions/ht503310
  • Lenovo Data Center Services Agreement
    http://support.lenovo.com/us/en/solutions/ht116628

Services

Lenovo Services is a dedicated partner to your success. Our goal is to reduce your capital outlays, mitigate your IT risks, and accelerate your time to productivity.

Note: Some service options may not be available in all markets or regions. For more information, go to https://www.lenovo.com/services. For information about Lenovo service upgrade offerings that are available in your region, contact your local Lenovo sales representative or business partner.

Here’s a more in-depth look at what we can do for you:

  • Asset Recovery Services

    Asset Recovery Services (ARS) helps customers recover the maximum value from their end-of-life equipment in a cost-effective and secure way. On top of simplifying the transition from old to new equipment, ARS mitigates environmental and data security risks associated with data center equipment disposal. Lenovo ARS is a cash-back solution for equipment based on its remaining market value, yielding maximum value from aging assets and lowering total cost of ownership for your customers. For more information, see the ARS page, https://lenovopress.com/lp1266-reduce-e-waste-and-grow-your-bottom-line-with-lenovo-ars.

  • Assessment Services

    An Assessment helps solve your IT challenges through an onsite, multi-day session with a Lenovo technology expert. We perform a tools-based assessment which provides a comprehensive and thorough review of a company's environment and technology systems. In addition to the technology based functional requirements, the consultant also discusses and records the non-functional business requirements, challenges, and constraints. Assessments help organizations like yours, no matter how large or small, get a better return on your IT investment and overcome challenges in the ever-changing technology landscape.

  • Design Services

    Professional Services consultants perform infrastructure design and implementation planning to support your strategy. The high-level architectures provided by the assessment service are turned into low level designs and wiring diagrams, which are reviewed and approved prior to implementation. The implementation plan will demonstrate an outcome-based proposal to provide business capabilities through infrastructure with a risk-mitigated project plan.

  • Basic Hardware Installation

    Lenovo experts can seamlessly manage the physical installation of your server, storage, or networking hardware. Working at a time convenient for you (business hours or off shift), the technician will unpack and inspect the systems on your site, install options, mount in a rack cabinet, connect to power and network, check and update firmware to the latest levels, verify operation, and dispose of the packaging, allowing your team to focus on other priorities.

  • Deployment Services

    When investing in new IT infrastructures, you need to ensure your business will see quick time to value with little to no disruption. Lenovo deployments are designed by development and engineering teams who know our Products & Solutions better than anyone else, and our technicians own the process from delivery to completion. Lenovo will conduct remote preparation and planning, configure & integrate systems, validate systems, verify and update appliance firmware, train on administrative tasks, and provide post-deployment documentation. Customer’s IT teams leverage our skills to enable IT staff to transform with higher level roles and tasks.

  • Integration, Migration, and Expansion Services

    Move existing physical & virtual workloads easily, or determine technical requirements to support increased workloads while maximizing performance. Includes tuning, validation, and documenting ongoing run processes. Leverage migration assessment planning documents to perform necessary migrations.

Regulatory compliance

The SE350 V2 conforms to the following standards:

  • ANSI/UL62368-1
  • IEC 62368-1 (CB Certificate and CB Test Report)
  • FCC - Verified to comply with Part 15 of the FCC Rules, Class A
  • Canada ICES-003, issue 7, Class A
  • CSA C22.2 No. 62368-1
  • CISPR 32, Class A, CISPR 35
  • Japan VCCI, Class A
  • Taiwan BSMI CNS15936, Class A; CNS15598-1; Section 5 of CNS15663
  • CE, UKCA Mark (EN55032 Class A, EN62368-1, EN55024, EN55035, EN61000-3-2, EN61000-3-3, (EU) 617/2013, and EN IEC 63000 (RoHS))
  • Korea KN32, Class A, KN35
  • Russia, Belorussia and Kazakhstan, TP EAC 037/2016 (for RoHS)
  • Russia, Belorussia and Kazakhstan, EAC: TP TC 004/2011 (for Safety); TP TC 020/2011 (for EMC)
  • EAC Russia, Belorussia and Kazakhstan, TR CU 020/2011 and TR CU 004/2011
  • Australia/New Zealand AS/NZS CISPR 32, Class A; AS/NZS 62368.1
  • UL Green Guard, UL2819
  • China CCC certificate, GB17625.1; GB4943.1; GB/T9254.1
  • China CECP certificate, CQC3135
  • China CELP certificate, HJ 2507-2011
  • Japanese Energy-Saving Act
  • Mexico NOM-019
  • TUV-GS (EN62368-1, and EK1-ITB2000)
  • India BIS 13252 (Part 1)
  • Germany GS
  • Brazil INMETRO
  • South Africa NRCS LOA
  • Ukraine UkrCEPRO
  • Morocco CMIM Certification (CM)

Top-of-rack Ethernet switches

The server supports the top-of-rack Ethernet switches that are listed in the following table. These switches have front-to-rear (reverse) airflow for use with servers where the networking ports are at the front of the server.

Table 44. Top-of-rack switches

Part numberDescription
1 Gb top-of-rack switches
7Y810012WWLenovo ThinkSystem NE0152T RackSwitch (Front to Rear)
715952FLenovo RackSwitch G8052 (Front to Rear)
10 Gb top-of-rack switches
7159A2XLenovo ThinkSystem NE1032 RackSwitch (Front to Rear)
7159B2XLenovo ThinkSystem NE1032T RackSwitch (Front to Rear)
7159C2XLenovo ThinkSystem NE1072T RackSwitch (Front to Rear)
715964FLenovo RackSwitch G8264 (Front to Rear)
7159DFXLenovo RackSwitch G8264CS (Front to Rear)
7159CFVLenovo RackSwitch G8272 (Front to Rear)
7159GR5Lenovo RackSwitch G8296 (Front to Rear)
7159BF7Lenovo RackSwitch G8124E (Front to Rear)
25 Gb top-of-rack switches
7159E2XLenovo ThinkSystem NE2572 RackSwitch (Front to Rear)
40 Gb top-of-rack switches
7159BFXLenovo RackSwitch G8332 (Front to Rear)
100 Gb top-of-rack switches
7159D2XLenovo ThinkSystem NE10032 RackSwitch (Front to Rear)

For more information, see the list of Product Guides in the Top-of-rack switches categories:

Uninterruptible power supply units

The following table lists the uninterruptible power supply (UPS) units that are offered by Lenovo.

Table 45. Uninterruptible power supply units
Part numberDescription
55941AXRT1.5kVA 2U Rack or Tower UPS (100-125VAC)
55941KXRT1.5kVA 2U Rack or Tower UPS (200-240VAC)
55942AXRT2.2kVA 2U Rack or Tower UPS (100-125VAC)
55942KXRT2.2kVA 2U Rack or Tower UPS (200-240VAC)
55943AXRT3kVA 2U Rack or Tower UPS (100-125VAC)
55943KXRT3kVA 2U Rack or Tower UPS (200-240VAC)
55945KXRT5kVA 3U Rack or Tower UPS (200-240VAC)
55946KXRT6kVA 3U Rack or Tower UPS (200-240VAC)
55948KXRT8kVA 6U Rack or Tower UPS (200-240VAC)
55949KXRT11kVA 6U Rack or Tower UPS (200-240VAC)
55948PXRT8kVA 6U 3:1 Phase Rack or Tower UPS (380-415VAC)
55949PXRT11kVA 6U 3:1 Phase Rack or Tower UPS (380-415VAC)
55943KT†ThinkSystem RT3kVA 2U Standard UPS (200-230VAC) (2x C13 10A, 2x GB 10A, 1x C19 16A outlets)
55943LT†ThinkSystem RT3kVA 2U Long Backup UPS (200-230VAC) (2x C13 10A, 2x GB 10A, 1x C19 16A outlets)
55946KT†ThinkSystem RT6kVA 5U UPS (200-230VAC) (2x C13 10A outlets, 1x Terminal Block output)
5594XKT†ThinkSystem RT10kVA 5U UPS (200-230VAC) (2x C13 10A outlets, 1x Terminal Block output)

† Only available in China and the Asia Pacific market.

For more information, see the list of Product Guides in the UPS category:
https://lenovopress.com/servers/options/ups

Power distribution units

The following table lists the power distribution units (PDUs) that are offered by Lenovo.

Table 46. Power distribution units
Part
number
Feature
code
Description

ANZ

ASEAN

Brazil

EET

MEA

RUCIS

WE

HTK

INDIA

JAPAN

LA

NA

PRC

0U Basic PDUs
00YJ776ATZY0U 36 C13/6 C19 24A 1 Phase PDUNYYNNNNNNYYYN
00YJ779ATZX0U 21 C13/12 C19 48A 3 Phase PDUNNYNNNYNNYYYN
00YJ777ATZZ0U 36 C13/6 C19 32A 1 Phase PDUYYNYYYYYYNNYY
00YJ778AU000U 21 C13/12 C19 32A 3 Phase PDUYYNYYYYYYNNYY
0U Switched and Monitored PDUs
00YJ783AU040U 12 C13/12 C19 Switched and Monitored 48A 3 Phase PDUNNYNNNYNNYYYN
00YJ781AU030U 20 C13/4 C19 Switched and Monitored 24A 1 Phase PDUNNYNYNYNNYYYN
00YJ782AU020U 18 C13/6 C19 Switched and Monitored 32A 3 Phase PDUYYYYYYYYYNYNY
00YJ780AU010U 20 C13/4 C19 Switched and Monitored 32A 1 Phase PDUYYYYYYYYYNYNY
1U Switched and Monitored PDUs
4PU7A90808C0D41U 18 C19/C13 Switched and monitored 48A 3P WYE PDU V2 ETL YYYYYYYYYYYYY
4PU7A81117BNDV1U 18 C19/C13 switched and monitored 48A 3P WYE PDU - ETLNNNNNNNNNNNYN
4PU7A90809C0DE1U 18 C19/C13 Switched and monitored 48A 3P WYE PDU V2 CE NNNNNYYNNNNNN
4PU7A81118BNDW1U 18 C19/C13 switched and monitored 48A 3P WYE PDU - CEYYYYYYYYYNYNY
4PU7A90810C0DD1U 18 C19/C13 Switched and monitored 80A 3P Delta PDU V2 YYYYYYYYYYYYY
4PU7A77467BLC41U 18 C19/C13 Switched and Monitored 80A 3P Delta PDUNNNNNNNNNYNYN
4PU7A90811C0DC1U 12 C19/C13 Switched and monitored 32A 3P WYE PDU V2 NNNNNYYNNNNNN
4PU7A77468BLC51U 12 C19/C13 switched and monitored 32A 3P WYE PDUYYYYYYYYYNYYY
4PU7A90812C0DB1U 12 C19/C13 Switched and monitored 60A 3P Delta PDU V2 NNNNNNNNNYNNN
4PU7A77469BLC61U 12 C19/C13 switched and monitored 60A 3P Delta PDUNNNNNNNNNNNYN
46M400258961U 9 C19/3 C13 Switched and Monitored DPI PDUYYYYYYYYYYYYY
46M400458941U 12 C13 Switched and Monitored DPI PDUYYYYYYYYYYYYY
46M400358971U 9 C19/3 C13 Switched and Monitored 60A 3 Phase PDUYYYYYYYYYYYYY
46M400558951U 12 C13 Switched and Monitored 60A 3 Phase PDUYYYYYYYYYYYYY
1U Ultra Density Enterprise PDUs (9x IEC 320 C13 + 3x IEC 320 C19 outlets)
71763NU6051Ultra Density Enterprise C19/C13 PDU 60A/208V/3PHNNYNNNNNNYYYN
71762NX6091Ultra Density Enterprise C19/C13 PDU ModuleYYYYYYYYYYYYY
1U C13 Enterprise PDUs (12x IEC 320 C13 outlets)
39M28166030DPI C13 Enterprise PDU Plus Module (WW)YYYYYYYYYYYYY
39Y89416010DPI C13 Enterprise PDU Module (WW)YYYYYYYYYYYYY
1U C19 Enterprise PDUs (6x IEC 320 C19 outlets)
39Y89486060DPI C19 Enterprise PDU Module (WW)YYYYYYYYYYYYY
39Y89236061DPI Three-phase 60A/208V C19 Enterprise PDU (US)NNYNNNYNNNYYN
1U Front-end PDUs (3x IEC 320 C19 outlets)
39Y89386002DPI Single-phase 30A/120V Front-end PDU (US)YYYYYYYYYYYYY
39Y89396003DPI Single-phase 30A/208V Front-end PDU (US)YYYYYYYYYYYYY
39Y89346005DPI Single-phase 32A/230V Front-end PDU (International)YYYYYYYYYYYYY
39Y89406004DPI Single-phase 60A/208V Front-end PDU (US)YNYYYYYNNYYYN
39Y89356006DPI Single-phase 63A/230V Front-end PDU (International)YYYYYYYYYYYYY
1U NEMA PDUs (6x NEMA 5-15R outlets)
39Y89055900DPI 100-127V NEMA PDUYYYYYYYYYYYYY
Line cords for 1U PDUs that ship without a line cord
40K961165044.3m, 32A/380-415V, EPDU/IEC 309 3P+N+G 3ph wye (non-US) Line CordYYYYYYYYYYYYY
40K961265024.3m, 32A/230V, EPDU to IEC 309 P+N+G (non-US) Line CordYYYYYYYYYYYYY
40K961365034.3m, 63A/230V, EPDU to IEC 309 P+N+G (non-US) Line CordYYYYYYYYYYYYY
40K961465004.3m, 30A/208V, EPDU to NEMA L6-30P (US) Line CordYYYYYYYYYYYYY
40K961565014.3m, 60A/208V, EPDU to IEC 309 2P+G (US) Line CordNNYNNNYNNYYYN
40K961765054.3m, 32A/230V, Souriau UTG Female to AS/NZ 3112 (Aus/NZ) Line CordYYYYYYYYYYYYY
40K961865064.3m, 32A/250V, Souriau UTG Female to KSC 8305 (S. Korea) Line CordYYYYYYYYYYYYY

For more information, see the Lenovo Press documents in the PDU category:
https://lenovopress.com/servers/options/pdu

Rack cabinets

The SE350 V2 supports installation in a rack when mounted in either the 1U E1 Enclosure or the 2U E2 Enclosure. See Mounting options for details.

Note: The E2 Enclosure is not supported in the 12U and 18U Micro Data Center rack cabinets.

The following table lists the supported rack cabinets.

Table 47. Rack cabinets
Part numberDescription
93072RX25U Standard Rack (1000mm)
93072PX25U Static S2 Standard Rack (1000mm)
7D6DA007WWThinkSystem 42U Onyx Primary Heavy Duty Rack Cabinet (1200mm)
7D6DA008WWThinkSystem 42U Pearl Primary Heavy Duty Rack Cabinet (1200mm)
1410-O42Lenovo EveryScale 42U Onyx Heavy Duty Rack Cabinet
1410-P42Lenovo EveryScale 42U Pearl Heavy Duty Rack Cabinet
93604PX42U 1200mm Deep Dynamic Rack
93614PX42U 1200mm Deep Static Rack
93634PX42U 1100mm Dynamic Rack
93634EX42U 1100mm Dynamic Expansion Rack
93074RX42U Standard Rack (1000mm)
7D6EA009WWThinkSystem 48U Onyx Primary Heavy Duty Rack Cabinet (1200mm)
7D6EA00AWWThinkSystem 48U Pearl Primary Heavy Duty Rack Cabinet (1200mm)
1410-O48Lenovo EveryScale 48U Onyx Heavy Duty Rack Cabinet
1410-P48Lenovo EveryScale 48U Pearl Heavy Duty Rack Cabinet

For specifications about these racks, see theLenovo Rack Cabinet Reference, available from:
https://lenovopress.com/lp1287-lenovo-rack-cabinet-reference

For more information, see the list of Product Guides in the Rack cabinets category:
https://lenovopress.com/servers/options/racks

Notes:

  • The following racks do not support the use of the cable management arm (CMA):
    • 25U racks, type 9307
    • 42U racks, type 9307

KVM console options

The following table lists the supported KVM consoles.

Table 48. KVM console
Part numberDescription
Consoles
4XF7A84188ThinkSystem 18.5" LCD Console (with US English keyboard)
4XF7A73009ThinkSystem 18.5" LCD console (with US English keyboard)
17238BX1U 18.5" Standard Console (without keyboard - see the next table)

The following table lists the keyboards supported with the 1U 18.5" Standard Console (now withdrawn).

Note: These keyboards are not supported with the ThinkSystem 18.5" LCD Console.

Table 49. Keyboards for 1U 18.5" Standard Console
Part numberDescription
7ZB7A05469ThinkSystem Keyboard w/ Int.Pointing Device USB - Arabic 253 RoHS v2
7ZB7A05468ThinkSystem Keyboard w/ Int. Pointing Device USB - Belg/UK 120 RoHS v2
7ZB7A05206ThinkSystem Keyboard w/ Int. Pointing Device USB - Czech 489 RoHS v2
7ZB7A05207ThinkSystem Keyboard w/ Int. Pointing Device USB - Danish 159 RoHS v2
7ZB7A05208ThinkSystem Keyboard w/ Int. Pointing Device USB - Dutch 143 RoHS v2
7ZB7A05210ThinkSystem Keyboard w/ Int. Pointing Device USB - Fr/Canada 445 RoHS v2
7ZB7A05209ThinkSystem Keyboard w/ Int. Pointing Device USB - French 189 RoHS v2
7ZB7A05211ThinkSystem Keyboard w/ Int. Pointing Device USB - German 129 RoHS v2
7ZB7A05212ThinkSystem Keyboard w/ Int. Pointing Device USB - Greek 219 RoHS v2
7ZB7A05213ThinkSystem Keyboard w/ Int. Pointing Device USB - Hebrew 212 RoHS v2
7ZB7A05214ThinkSystem Keyboard w/ Int. Pointing Device USB - Hungarian 208 RoHS v2
7ZB7A05215ThinkSystem Keyboard w/ Int. Pointing Device USB - Italian 141 RoHS v2
7ZB7A05216ThinkSystem Keyboard w/ Int. Pointing Device USB - Japanese 194 RoHS v2
7ZB7A05217ThinkSystem Keyboard w/ Int. Pointing Device USB - Korean 413 RoHS v2
7ZB7A05218ThinkSystem Keyboard w/ Int. Pointing Device USB - LA Span 171 RoHS v2
7ZB7A05219ThinkSystem Keyboard w/ Int. Pointing Device USB - Norwegian 155 RoHS v2
7ZB7A05220ThinkSystem Keyboard w/ Int. Pointing Device USB - Polish 214 RoHS v2
7ZB7A05221ThinkSystem Keyboard w/ Int. Pointing Device USB - Portugese 163 RoHS v2
7ZB7A05222ThinkSystem Keyboard w/ Int. Pointing Device USB - Russian 441 RoHS v2
7ZB7A05223ThinkSystem Keyboard w/ Int. Pointing Device USB - Slovak 245 RoHS v2
7ZB7A05231ThinkSystem Keyboard w/ Int. Pointing Device USB - Slovenian 234 RoHS v2
7ZB7A05224ThinkSystem Keyboard w/ Int. Pointing Device USB - Spanish 172 RoHS v2
7ZB7A05225ThinkSystem Keyboard w/ Int. Pointing Device USB - Swed/Finn 153 RoHS v2
7ZB7A05226ThinkSystem Keyboard w/ Int. Pointing Device USB - Swiss F/G 150 RoHS v2
7ZB7A05227ThinkSystem Keyboard w/ Int. Pointing Device USB - Thai 191 RoHS v2
7ZB7A05467ThinkSystem Keyboard with Int. Pointing Device USB - Trad Chinese/US 467 RoHS v2
7ZB7A05228ThinkSystem Keyboard w/ Int. Pointing Device USB - Turkish 179 RoHS v2
7ZB7A05229ThinkSystem Keyboard w/ Int. Pointing Device USB - UK Eng 166 RoHS v2
7ZB7A05470ThinkSystem Keyboard w/ Int. Pointing Device USB - US Eng 103P RoHS v2
7ZB7A05230ThinkSystem Keyboard w/ Int. Pointing Device USB - US Euro 103P RoHS v2

The following table lists the available KVM switches and the options that are supported with them.

Table 50. KVM switches and options
Part numberDescription
KVM Console switches
1754D1TThinkSystem Digital 2x1x16 KVM Switch (DVI video output port)
1754A1TThinkSystem Analog 1x8 KVM Switch (DVI video output port)
1754D2XGlobal 4x2x32 Console Manager (GCM32)
1754D1XGlobal 2x2x16 Console Manager (GCM16)
1754A2XLocal 2x16 Console Manager (LCM16)
1754A1XLocal 1x8 Console Manager (LCM8)
Cables for ThinkSystem Digital and Analog KVM Console switches
4X97A11108ThinkSystem VGA to DVI Conversion Cable
4X97A11109ThinkSystem Single-USB Conversion Cable for Digital KVM
4X97A11107ThinkSystem Dual-USB Conversion Cable for Digital KVM
4X97A11106ThinkSystem USB Conversion Cable for Analog KVM
Cables for GCM and LCM Console switches
43V6147Single Cable USB Conversion Option (UCO)
39M2895USB Conversion Option Pack
46M5383Virtual Media Conversion Option Gen2 (VCO2)
46M5382Serial Conversion Option (SCO)

For more information, see the list of Product Guides in the KVM Switches and Consoles category:
http://lenovopress.com/servers/options/kvm

Lenovo Financial Services

Lenovo Financial Services reinforces Lenovo’s commitment to deliver pioneering products and services that are recognized for their quality, excellence, and trustworthiness. Lenovo Financial Services offers financing solutions and services that complement your technology solution anywhere in the world.

We are dedicated to delivering a positive finance experience for customers like you who want to maximize your purchase power by obtaining the technology you need today, protect against technology obsolescence, and preserve your capital for other uses.

We work with businesses, non-profit organizations, governments and educational institutions to finance their entire technology solution. We focus on making it easy to do business with us. Our highly experienced team of finance professionals operates in a work culture that emphasizes the importance of providing outstanding customer service. Our systems, processes and flexible policies support our goal of providing customers with a positive experience.

We finance your entire solution. Unlike others, we allow you to bundle everything you need from hardware and software to service contracts, installation costs, training fees, and sales tax. If you decide weeks or months later to add to your solution, we can consolidate everything into a single invoice.

Our Premier Client services provide large accounts with special handling services to ensure these complex transactions are serviced properly. As a premier client, you have a dedicated finance specialist who manages your account through its life, from first invoice through asset return or purchase. This specialist develops an in-depth understanding of your invoice and payment requirements. For you, this dedication provides a high-quality, easy, and positive financing experience.

For your region-specific offers, please ask your Lenovo sales representative or your technology provider about the use of Lenovo Financial Services. For more information, see the following Lenovo website:

https://www.lenovo.com/us/en/landingpage/lenovo-financial-services/

Seller training courses

The following sales training courses are offered for employees and partners (login required). Courses are listed in date order.

  1. Lenovo Data Center Product Portfolio
    2024-05-29 | 20 minutes | Employees and Partners
    Details

    Lenovo Data Center Product Portfolio

    This course introduces the Lenovo data center portfolio, and covers servers, storage, storage networking, and software-defined infrastructure products. After completing this course about Lenovo data center products, you will be able to identify product types within each data center family, describe Lenovo innovations that this product family or category uses, and recognize when a specific product should be selected.

    Published: 2024-05-29
    Length: 20 minutes
    Employee link: Grow@Lenovo
    Partner link: Lenovo Partner Learning
    Course code: SXXW1110r7

  2. Think AI Weekly: School Safety at the Edge
    2024-05-13 | 60 minutes | Employees Only
    Details

    Think AI Weekly: School Safety at the Edge

    Join Alejandro Perez, ISG/IDG Edge Business Development, Allen Holmes with ISG AI Business Development, and Lauren Allen ISG/IDG Go To Market Strategist as they discuss school security, AI computer vision and Lenovo ThinkEdge School solutions.
    • AI solution capabilities for campus safety
    • Safety solutions with ThinkEdge SE70 and SE450
    • Walkthrough of La Jolla and other use cases

    Published: 2024-05-13
    Length: 60 minutes
    Employee link: Grow@Lenovo
    Course code: DTAIW103

  3. VTT: HCI at the Edge and Dick's Sporting Goods_May 2024
    2024-05-08 | 60 minutes | Employees Only
    Details

    VTT: HCI at the Edge and Dick's Sporting Goods_May 2024

    Join Adam Mandlebloom, ISG SDI Technical Product Manager, and Bryan Maskrey, ISG Technical Sales, as they explore Lenovo HCI solutions at the Edge and how one such solution is being positioned to resolve business challenges at a national retail company, Dick’s Sporting Goods. Topics covered will include
    •Hyperconverged Edge to Cloud today, and looking forward
    •ThinkAgile for AI/ML - Cost effective GPU utilization
    •Local Cluster Management integration
    •Decision points and architecting the solution for Dick’s Sporting Goods

    Published: 2024-05-08
    Length: 60 minutes
    Employee link: Grow@Lenovo
    Course code: DVEDG212

  4. VTT: Management of Low-End Edge - March 2024
    2024-03-13 | 64 minutes | Employees Only
    Details

    VTT: Management of Low-End Edge - March 2024

    XClarity Orchestrator supports the management of both ISG XCC-based servers and IDG low-end edge devices. This session will cover the architecture of the current solution, along with a demo. In addition, a proposed new architecture for future support of low-end edge devices will be covered

    Published: 2024-03-13
    Length: 64 minutes
    Employee link: Grow@Lenovo
    Course code: DVSYS207

  5. Business Problems Addressed with Lenovo Data & Analytics Solutions
    2024-01-31 | 20 minutes | Employees and Partners
    Details

    Business Problems Addressed with Lenovo Data & Analytics Solutions

    Data is the quantities, characters, or symbols on which operations are performed by a computer, which is then stored and transmitted in the form of electrical signals and recorded on magnetic, optical, solid state, or mechanical recording media. All different types of organizations rely more and more on their data to gain valuable insights and improve their business. As expected, they will have challenges with gaining this insight. In this course we will discuss those challenges and problems our customers face and describe how Lenovo Data and Analytics Solutions can help customers solve each problem.

    After completing this training, you will be able to define the following common problems for databases and big data and describe how Lenovo can help customers solve each problem: scalability, management, performance, protection, security, knowledge/skill, and technology evolution.

    After completing this training, you will be able to define the following common problems for databases and big data and describe how Lenovo can help customers solve each problem: scalability, management, performance, protection, security, knowledge/skill, and technology evolution.

    Published: 2024-01-31
    Length: 20 minutes
    Employee link: Grow@Lenovo
    Partner link: Lenovo Partner Learning
    Course code: DSOLP200

  6. Family Introduction: Edge Servers
    2024-01-22 | 18 minutes | Employees and Partners
    Details

    Family Introduction: Edge Servers

    This course introduces the concept of edge servers. Edge servers are used at the edge of an IoT environment, where they perform pre-processing of data, and data forwarding to core environments.
    Course Objectives:
    •Describe the Internet of Things (IoT)
    •Define an edge server
    •Discuss edge server features

    Published: 2024-01-22
    Length: 18 minutes
    Employee link: Grow@Lenovo
    Partner link: Lenovo Partner Learning
    Course code: SXXW1105

  7. VTT: VMware and Lenovo - Transforming Industries with VMware Edge Compute Jan. 2024
    2024-01-10 | 60 minutes | Employees Only
    Details

    VTT: VMware and Lenovo - Transforming Industries with VMware Edge Compute Jan. 2024

    Join Josh David from VMware and Trent Richardson from Lenovo as they discuss the latest news from Project Bullwark, and what’s new from the VMware Edge Compute Stack. Topics will include VMware Edge real-time capabilities, Edge Orchestration, and more. Josh and Trent will also discuss determining factors when choosing between the ThinkEdge SE350 V2 and ThinkEdge SE360 V2. Together they will explore what lies in the near future for Lenovo and VMware at the Edge.

    Published: 2024-01-10
    Length: 60 minutes
    Employee link: Grow@Lenovo
    Course code: DVEDG210

  8. Partner Technical Webinar - Tech World 23 Review
    2023-12-22 | 60 minutes | Employees and Partners
    Details

    Partner Technical Webinar - Tech World 23 Review

    In this 60-minute replay, Kenny James, Lenovo Channel Sales Engineering Director, joined us to give a Channel CTO’s perspective on this year's Tech World 2023 conference where the theme was AI for All.

    Published: 2023-12-22
    Length: 60 minutes
    Employee link: Grow@Lenovo
    Partner link: Lenovo Partner Learning
    Course code: 121523

  9. Basics of the Edge Ecosystem for Sellers
    2023-12-15 | 20 minutes | Employees and Partners
    Details

    Basics of the Edge Ecosystem for Sellers

    The purpose of this learning module is to familiarize Lenovo field sales, inside sales and partners with the Edge ecosystem and how Lenovo fits into the Edge space.

    •Explain the basics of an Edge Ecosystem
    •Articulate the inherent challenges of Edge Computing
    •Present how Lenovo fits in the Edge Ecosystem

    Published: 2023-12-15
    Length: 20 minutes
    Employee link: Grow@Lenovo
    Partner link: Lenovo Partner Learning
    Course code: DTEF101

  10. The 10-minute Edge conversation for Lenovo Sellers
    2023-12-14 | 20 minutes | Employees and Partners
    Details

    The 10-minute Edge conversation for Lenovo Sellers

    The purpose of this course is to enable sellers to have a 10 to 15-minute customer conversation addressing the relevancy of Edge solutions to the customer business.

    Learning Objectives:

    •Prepare for the initial customer conversation
    •Hold a 10-minute Edge Operational Technology (OT) conversation
    •Take the appropriate steps to progress the sale

    Published: 2023-12-14
    Length: 20 minutes
    Employee link: Grow@Lenovo
    Partner link: Lenovo Partner Learning
    Course code: DTEF103

  11. Intel and Lenovo Bringing AI Everywhere
    2023-12-13 | 50 minutes | Employees Only
    Details

    Intel and Lenovo Bringing AI Everywhere

    Join Patrick Cassleman of Intel as he discusses how Lenovo and Intel can partner to help customers develop and deploy sustainable AI hardware and software from the edge to the cloud. Patrick will discuss Intel’s full AI portfolio, plus available features and tools to help your customers attain sustainable AI.

    Published: 2023-12-13
    Length: 50 minutes
    Employee link: Grow@Lenovo
    Course code: DVEDG209

  12. VTT: Lenovo in the Era of the Edge-June 2023
    2023-12-04 | 60 minutes | Employees and Partners
    Details

    VTT: Lenovo in the Era of the Edge-June 2023

    Join Richard Jenkins from the Lenovo Edge Computing Business Development group as he discusses how Lenovo fits in the era of the Edge. Topics covered in this VTT session include:
    - customer use cases at the Edge
    - the needed consortium to build an Edge Solution
    - Lenovo edge portfolio
    - The advantages of LOC-A and XClarity at the Edge

    Published: 2023-12-04
    Length: 60 minutes
    Employee link: Grow@Lenovo
    Partner link: Lenovo Partner Learning
    Course code: DVEDG201

  13. VTT: ThinkEdge SE350V2 and ThinkEdge SE360 V2, Wave 2 - What's new for bringing AI and computing to the source of the data?
    2023-11-03 | 75 minutes | Employees Only
    Details

    VTT: ThinkEdge SE350V2 and ThinkEdge SE360 V2, Wave 2 - What's new for bringing AI and computing to the source of the data?

    Join Aaron Shao, Sr. Product Manager from Lenovo ThinkEdge Business Unit, as he explores details of the added features for the SE350 V2 and SE360 V2 in Wave 2. Aaron will cover generation transition and product selling points as he discusses customer advantages of the SE350 V2 and SE360 V2 in the context of AI and compute.

    Published: 2023-11-03
    Length: 75 minutes
    Employee link: Grow@Lenovo
    Course code: DVEDG207

  14. VTT: Edge Product Innovation, ISVs, and Market trends - AP & PRC, Oct. 2023
    2023-10-12 | 60 minutes | Employees Only
    Details

    VTT: Edge Product Innovation, ISVs, and Market trends - AP & PRC, Oct. 2023

    Join Richard Jenkins from the AP Edge solutions group as he discusses the difference between Industrial Internet of things (IoT) and Operational Technology (OT). Richard takes a look at how both are relevant to combining edge servers with hybrid cloud architecture. Topics include:
    •Integration of ISV Concepts
    •Edge serving clusters and megaclusters
    •Container designs for SE10, SE30 & SE50

    Published: 2023-10-12
    Length: 60 minutes
    Employee link: Grow@Lenovo
    Course code: DVEDG206

  15. VTT: Edge Product Innovation, ISVs, and Market trends - EMEA, LA & NA, Oct. 2023
    2023-10-11 | 60 minutes | Employees Only
    Details

    VTT: Edge Product Innovation, ISVs, and Market trends - EMEA, LA & NA, Oct. 2023

    Join Per Ljungstrom and Anthony Sayers as they discuss the difference between Industrial Internet of things (IoT) and Operational Technology (OT). They look at how both are relevant to combining edge servers with hybrid cloud architecture. Topics include:
    •Integration of ISV Concepts
    •Edge serving clusters and megaclusters
    •Container designs for SE10, SE30 & SE50

    Published: 2023-10-11
    Length: 60 minutes
    Employee link: Grow@Lenovo
    Course code: DVEDG205

  16. Partner Technical Webinar - StorMagic
    2023-10-02 | 60 minutes | Employees and Partners
    Details

    Partner Technical Webinar - StorMagic

    In this 60-minute replay, Wes Ganeko and Craig Collier from StorMagic reviewed the need for Storage at the Edge, StorMagic’s involvement in the Lenovo AI Innovators program and a deep dive into SvSAN, StorMagic’s flagship product for simple hyperconverged storage.

    Published: 2023-10-02
    Length: 60 minutes
    Employee link: Grow@Lenovo
    Partner link: Lenovo Partner Learning
    Course code: 092923

  17. Intro to Edge: 3Ws of Edge Computing for Lenovo Sellers
    2023-09-14 | 13 minutes | Employees and Partners
    Details

    Intro to Edge: 3Ws of Edge Computing for Lenovo Sellers

    This course provides fundamental concepts and a learning foundation for those who are new to the data center and to computing at the Edge. It defines where is the Edge, identifies what are the business drivers for edge computing, and discusses why is edge computing important to Lenovo. September 2023

    Published: 2023-09-14
    Length: 13 minutes
    Employee link: Grow@Lenovo
    Partner link: Lenovo Partner Learning
    Course code: DTEF100

  18. Lenovo Solutions for the Edge - Who Are the Customers?
    2023-09-14 | 25 minutes | Employees and Partners
    Details

    Lenovo Solutions for the Edge - Who Are the Customers?

    This course is focused on enabling sellers to identify opportunities for Lenovo Edge and Edge AI Solutions. Topics include a general overview of the Lenovo Edge portfolio and recognizing how edge computing can benefit customers.

    Course Objectives:
    •Identify Lenovo Edge Opportunities
    •Recognize how an Edge solution would benefit your customer
    •Provide a general overview of Lenovo solutions at the Edge
    •Identify key points for your customer Edge conversation

    Published: 2023-09-14
    Length: 25 minutes
    Employee link: Grow@Lenovo
    Partner link: Lenovo Partner Learning
    Course code: DTEF102

  19. Family Portfolio - Edge
    2023-09-12 | 15 minutes | Employees and Partners
    Details

    Family Portfolio - Edge

    This course introduces edge environments, and the roles played by Lenovo edge servers and edge clients in those environments. It looks briefly at use cases for these edge devices.
    When you have completed this course, you should be able to list the edge solutions in the Lenovo portfolio, describe the features of each solution, and determine which solution is best suited to a specific environment.

    Published: 2023-09-12
    Length: 15 minutes
    Employee link: Grow@Lenovo
    Partner link: Lenovo Partner Learning
    Course code: SXXW2513r2

  20. VTT: VMware Edge Compute Stack, August 2023
    2023-08-17 | 60 minutes | Employees Only
    Details

    VTT: VMware Edge Compute Stack, August 2023

    Edge Compute drives business transformation in sectors like retail, manufacturing & utilities. It intersects with IoT sensors, robotics & AI, and supports use cases requiring computing closer to operations. Implementing Edge Compute at scale requires a platform supporting verticalized applications, manageability, reliability & security. Join Josh David from VMware and Alejandro Perez from Lenovo as they discuss how the VMware Edge Stack enables real-time intelligence & immersive experiences at the Edge.

    Published: 2023-08-17
    Length: 60 minutes
    Employee link: Grow@Lenovo
    Course code: DVEDG203

  21. VTT: SAP HANA Transition and Refresh Opportunity - July 2023
    2023-07-14 | 60 minutes | Employees Only
    Details

    VTT: SAP HANA Transition and Refresh Opportunity - July 2023

    In this session, we cover:
    - What Next for SAP Clients?
    - Lenovo Opportunity
    - Lenovo Portfolio for SAP Solutions
    - RISE with SAP

    Published: 2023-07-14
    Length: 60 minutes
    Employee link: Grow@Lenovo
    Course code: DVDAT202

  22. Partner Technical Webinar - ThinkEdge SE350 V2 & SE360 V2 Update
    2023-07-13 | 60 minutes | Employees and Partners
    Details

    Partner Technical Webinar - ThinkEdge SE350 V2 & SE360 V2 Update

    July 7, 2023 – in this 60-minute replay, Benoit Robert, Director - Edge Server Product Management, reviewed the ThinkEdge portfolio specifically the SE350v2 and SE360v2. Benoit discussed the key differences between the 2 edge servers with a focus on form factors and use cases.

    Published: 2023-07-13
    Length: 60 minutes
    Employee link: Grow@Lenovo
    Partner link: Lenovo Partner Learning
    Course code: 070723

  23. Partner Technical Webinar - Server Review with Mark Bica
    2023-06-20 | 60 minutes | Employees and Partners
    Details

    Partner Technical Webinar - Server Review with Mark Bica

    In this 60-minute replay, Mark Bica, Lenovo ThinkSystem Brand Manager, reviewed currently ThinkSystem Server portfolio. He highlighted recent server announcements including the SE350 V2, SE360 V2 and SR675 V3. Joe Murphy, Lenovo Solution Architect concluded the session with a demo of how to get Estimated Ship Dates in DCSC.

    Published: 2023-06-20
    Length: 60 minutes
    Employee link: Grow@Lenovo
    Partner link: Lenovo Partner Learning
    Course code: 061623

  24. FY24Q1 AI Launch
    2023-06-14 | 15 minutes | Employees and Partners
    Details

    FY24Q1 AI Launch

    This course covers the exciting announcements that Lenovo is making about its commitment to AI. Not only has Lenovo pledged to invest $1B in AI over the next three years, and committed $100M to bolster the Lenovo AI Innovators Program, but there are also some exciting product announcements.

    Once you complete this course, you should be able to define intelligence and artificial intelligence, describe a digital twin, and discuss the three key points of the Lenovo AI launch: investment in AI, a new AI-capable data center server, and new AI-capable edge servers.

    Published: 2023-06-14
    Length: 15 minutes
    Employee link: Grow@Lenovo
    Partner link: Lenovo Partner Learning
    Course code: SXXW2516

  25. Lenovo XClarity Management Hub for Edge Server Devices
    2023-06-08 | 50 minutes | Employees and Partners
    Details

    Lenovo XClarity Management Hub for Edge Server Devices

    This course offers a comprehensive overview and demonstration of the enhanced capability to manage ThinkEdge Server Devices through Lenovo XClarity Management Hub in Lenovo XClarity Orchestrator (LXCO).

    Published: 2023-06-08
    Length: 50 minutes
    Employee link: Grow@Lenovo
    Partner link: Lenovo Partner Learning
    Course code: DXCO201

  26. Lenovo XClarity Management Hub for Edge Client Devices
    2023-06-08 | 50 minutes | Employees and Partners
    Details

    Lenovo XClarity Management Hub for Edge Client Devices

    This course offers a comprehensive overview and demonstration of the enhanced capability to manage ThinkEdge Client Devices through Lenovo XClarity Management Hub in Lenovo XClarity Orchestrator (LXCO).

    Published: 2023-06-08
    Length: 50 minutes
    Employee link: Grow@Lenovo
    Partner link: Lenovo Partner Learning
    Course code: DXCO202

  27. Family Portfolio: Intel Edge Servers
    2023-06-07 | 15 minutes | Employees and Partners
    Details

    Family Portfolio: Intel Edge Servers

    This course introduces two new Lenovo ThinkEdge servers: the ThinkEdge SE350 V2 and ThinkEdge SE360 V2.
    After completing this course, you will be able to list the Intel edge servers in the Lenovo portfolio, describe the features of each server and determine which server is best suited to a specific environment.

    Published: 2023-06-07
    Length: 15 minutes
    Employee link: Grow@Lenovo
    Partner link: Lenovo Partner Learning
    Course code: SXXW2510r2

  28. Lenovo FY24Q2 AI Announcement QH
    2023-06-07 | 3 minutes | Employees and Partners
    Details

    Lenovo FY24Q2 AI Announcement QH

    This Quick Hit covers the exciting announcements Lenovo is making about its commitment to AI. Lenovo has pledged to invest $1B in AI over the next three years, and has committed $100M to bolster the Lenovo AI Innovators Program to develop AI-Ready solutions faster. Two new servers are being added to the already impressive Lenovo Edge portfolio – the ThinkEdge SE350 V2 and ThinkEdge SE360 V2. These servers offer a wide operating temperature range and the ruggedness to handle shock, vibration, and airborne contaminants. The SE360 V2 supports GPUs, making it ideal for AI at the edge. Both servers support the new time-sensitive networking protocol, TSN, to ensure that response times are low and deterministic.
    Note: This course is presented as audio only. There are no slides or video.

    Published: 2023-06-07
    Length: 3 minutes
    Employee link: Grow@Lenovo
    Partner link: Lenovo Partner Learning
    Course code: SXXW2516a

  29. Partner Technical Webinar - Smart Cities with ThinkEdge
    2022-12-13 | 60 minutes | Partners Only
    Details

    Partner Technical Webinar - Smart Cities with ThinkEdge

    In this 60-minute replay, Alejandro Perez, Lenovo Americas Edge Solutions Leader, discussed the Edge applications of Smart Cities, specifically the City of Barcelona. Alejandro reviewed the key uses of the solution and the underlying architecture including the Lenovo SE350, SE450 and Lenovo Open Cloud Automation software.

    Published: 2022-12-13
    Length: 60 minutes
    Partner link: Lenovo Partner Learning
    Course code: 120922

  30. Technical Champions Webinar: Edge Computing Enables New Possibilities
    2022-12-09 | 64 minutes | Employees Only
    Details

    Technical Champions Webinar: Edge Computing Enables New Possibilities

    The Lenovo launch of both ThinkEdge SE350 and SE450 helps to resolve edge computing requirements and enables new possibilities for a variety of verticals. Join Aaron Shao, Lenovo Edge Product Manager, as he discusses the big picture of edge computing and positioning of the Lenovo ThinkEdge portfolio. Aaron will take a deep dive into the latest news from the most GPU rich edge server in the industry, the Lenovo ThinkEdge SE450. Two outstanding customer stories and their application of Edge computing will also be featured as well.

    Published: 2022-12-09
    Length: 64 minutes
    Employee link: Grow@Lenovo
    Course code: DTEO101

  31. Technical Champions Webinar: Lenovo Edge Solutions: Unleash the Power of AI Solutions at the Edge
    2022-10-13 | 60 minutes | Employees and Partners
    Details

    Technical Champions Webinar: Lenovo Edge Solutions: Unleash the Power of AI Solutions at the Edge

    View this Technical Champions Webinar (recorded October 10, 2022) to learn about Lenovo's Edge solutions. Join Alejandro Perez Quintero as he discusses the elements of Edge computing, the growth of the Edge and the connection with AI.

    This webinar covers:
    - Drivers for Edge Technology
    - Lenovo Edge Solutions
    - Customer use cases

    Published: 2022-10-13
    Length: 60 minutes
    Employee link: Grow@Lenovo
    Partner link: Lenovo Partner Learning
    Course code: DEDGP100

1-10 of 31 courses.

Related publications and links

For more information, see these resources:

  • ThinkSystem SE350 V2 drivers and support
    https://datacentersupport.lenovo.com/us/en/
  • Lenovo ThinkSystem SE350 V2 product page:
  • https://www.lenovo.com/us/en/p/servers-storage/servers/edge/ThinkEdge-SE350-V2/LEN21TS0018
  • Interactive 3D Tour of the ThinkEdge SE350 V2:
    https://lenovopress.lenovo.com/lp1751
  • ServerProven hardware compatibility:
    https://serverproven.lenovo.com/
  • Lenovo Server Options:
    https://serveroption.lenovo.com/

Related product families

Product families related to this document are the following:

  • Edge Computing and Internet of Things (IoT)
  • Edge Servers
  • ThinkEdge SE350 V2 Server

Trademarks

Lenovo and the Lenovo logo are trademarks or registered trademarks of Lenovo in the United States, other countries, or both. A current list of Lenovo trademarks is available on the Web at https://www.lenovo.com/us/en/legal/copytrade/.

The following terms are trademarks of Lenovo in the United States, other countries, or both:
Lenovo®
Bootable Media Creator
Flex System
Lenovo Services
RackSwitch
ServerProven®
System x®
ThinkAgile®
ThinkEdge®
ThinkShield®
ThinkServer®
ThinkSystem®
TruDDR4
UpdateXpress System Packs
XClarity®

The following terms are trademarks of other companies:

Intel® and Xeon® are trademarks of Intel Corporation or its subsidiaries.

Linux® is the trademark of Linus Torvalds in the U.S. and other countries.

Microsoft®, ActiveX®, Azure®, Hyper-V®, PowerShell, Windows PowerShell®, Windows Server®, and Windows® are trademarks of Microsoft Corporation in the United States, other countries, or both.

Other company, product, or service names may be trademarks or service marks of others.

Lenovo ThinkEdge SE350 V2 Server Product Guide (2024)

References

Top Articles
Latest Posts
Article information

Author: Arielle Torp

Last Updated:

Views: 6123

Rating: 4 / 5 (61 voted)

Reviews: 92% of readers found this page helpful

Author information

Name: Arielle Torp

Birthday: 1997-09-20

Address: 87313 Erdman Vista, North Dustinborough, WA 37563

Phone: +97216742823598

Job: Central Technology Officer

Hobby: Taekwondo, Macrame, Foreign language learning, Kite flying, Cooking, Skiing, Computer programming

Introduction: My name is Arielle Torp, I am a comfortable, kind, zealous, lovely, jolly, colorful, adventurous person who loves writing and wants to share my knowledge and understanding with you.